Datalogic Compact 2D Reader Matrix-2000 Manual de instrucciones Pagina 58

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 108
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 57
MATRIX-2000™ REFERENCE MANUAL
5
5.5.3 RS485 Half-Duplex Interface
The opto-isolated RS485 half-duplex (3 wires + shield) interface is available for polled
communication protocols.
It can be used for multidrop connections with a Datalogic Multiplexer, (see Figure 70 and par.
6.4) exploiting a proprietary protocol based on polled mode called MUX32 protocol, where a
master device polls slave devices to collect data.
The following pins of the 25-pin connector are used for RS485 half-duplex communication:
Pin Name Function
2 RTX+ RS485 Receive/Transmit Data (+)
4 RTX- RS485 Receive/Transmit Data (-)
7 GND_ISO Main opto-isolated reference ground
MATRI
X
RTX-
RTX+
MULITPLEXER
RTX485-
RTX485+
GND_ISO
RS485REF
SHIELD
4
2
7
1
Earth Ground Earth Ground
Chassis
Figure 69 - RS485 Half-duplex Connections
This interface is forced by software when the protocol selected is MUX32 protocol.
In a Multiplexer layout, the Multidrop address must also be set via serial channel by the
VisiSet™ utility or by the Host Programming Mode.
48
Vista de pagina 57