MATRIX 210™ HOST MODE PROGRAMMING
68
4
PARAMETER TYPE SEL STRING DATA
54 = Code 32
55 = Locator Edge
Data #n 2 <ESC> z #n Length: 0 to 3116
Wildcard Character
#n
2 <ESC> Y #n Length: 1
Placeholder
Character #n
2 <ESC> Z #n Length: 1
NOTE
Special characters <FE
H
> and <FD
H
> must be added after #n in the
programming string to indicate parameter Depth > 9. Refer to paragraph 3.2
for further details.
4.20 SYMBOL VERIFICATION
PARAMETER TYPE SEL STRING DATA
ISO-IEC 16022-18004
Status 1 1 <ESC> R A 0 = Disabled
1 = Enabled
ISO-IEC 15415-15416 SETUP
Aperture Mode 1 1 <ESC> R B 0 = Automatic
1 = Custom
Aperture (mils) 0 <ESC> R C Range: 0 to 1000
Angle 0 <ESC> R D Range: 0 to 90
Light Wavelength (nm) 1 1 <ESC> R E 0 = White
1 = 660
2 = 760
ISO-IEC 15415
Status 1 1 <ESC> R F 0 = Disabled
1 = Enabled
ISO-IEC 15416
Status 1 1 <ESC> R G 0 = Disabled
1 = Enabled
Grade Type 1 1 <ESC> R H 0 = 10 Scans
1 = Media
2 = Media & 10 Scans
AS9132A
Status 1 1 <ESC> R I 0 = Disabled
1 = Enabled
PARAMETER TYPE SEL STRING DATA
Module Shape 1 1 <ESC> R J 0 = Dot
1 = Square
Marking Method 1 <ESC> R K 0 = Laser/Chemical
1 = Inkjet/Dot Peen