AccuLazr™ AL5010 Product Line Manual Appendix D: Networking Guide 203
Connection Manager Object (06
HEX
)
This object has no attributes.
TCP Object (F5
HEX -
1 Instance)
Class Attributes
Attribute ID Name Data Type Data Value Access
Rule
1 Revision UINT 1 Get
Instance Attributes
Attribute ID Name Data Type Default
Data Value
Access
Rule
1 Status DWORD 1 Get
2 Configuration Capability DWORD 0 Get
3 Configuration Control DWORD 0 Get
4 Physical Link Object
Structure of:
Path Size
Path
UINT
Array Of WORD
2
0x20F6
0x2401
Get
5 Interface Configuration
Structure of:
IP Address
Network Mask
Gateway Address
Name Server
Name Server 2
Domain Name Size
Domain Name
UDINT
UDINT
UDINT
UDINT
UDINT
UINT
STRING
0
0
0
0
0
0
0
Get
6 Host Name
Structure of:
Host Name Size
Host Name
UINT
STRING
0
0
Get
Common Services
Implemented for Service Code
Class Level Instance Level
Service Name
0E
HEX
Yes Yes Get_Attribute_Single
Ethernet Link Object (F6
HEX
- 1 Instance)
Class Attributes
Attribute ID Name Data Type Data Value Access
Rule
1 Revision UINT 1 Get
Instance Attributes
Attribute ID Name Data Type Default
Data Value
Access
Rule
1 Interface Speed UDINT 100 Get
2 Interface Flags DWORD 3 Get
3 Physical Address USINT Array[6] 0 Get
Common Services
Implemented for Service Code
Class Level Instance Level
Service Name
0E
HEX
Yes Yes Get_Attribute_Single
A4-AL5010_Networking_Guide_R20.doc Accu-Sort Systems, Inc.