TECHNICAL FEATURES
Heron™ D140
Electrical Features
Power supply 5 Vdc ± 5%
Consumption
Operating
Stand by
180 mA @ 5 Vdc
50 mA @ 5 Vdc
CCD Scan Rate 256 scans/sec
Max output scan rate 144 scans/sec
Reading Indicators LED, Good Read Spot, Beeper
Optical Features
Sensor CCD solid state (2048 pixels)
Illuminator LED array
Wavelength 630 ~ 670 nm
Max. LED Output Power 0.31 mW
LED Safety Class Class 1 EN 60825-1
Reading Field see reading diagram
Max. Resolution 0.12 mm (5 mils)
PCS min. 15% (Datalogic Test Chart)
Environmental Features
Working Temperature
0 °C to + 40 °C
Storage Temperature
-20 °C to + 60 °C
Humidity 90% non condensing
Drop resistance
(on concrete)
IEC 68-2-32 Test ED
1.8 m
Protection Class IP30
Mechanical Features
Weight (without cable) about 165 g (5.8 oz)
Cable length
(CAB 397 – fully extended)
(CAB 396 – fully extended)
2.60 m (8 ft 5 in)