Magellan® 9500/9500Ω9504/9504Ωwith SmartSentry®Product Reference Guide
8 Magellan® 9500Standard 2 of 5 Label ID ... 6-273Standard 2 of 5 Le
4-14 Magellan® 9500NOTES
Product Reference Guide 5-1Chapter 5CalibrationA number of situations require the scale to be calibrated. They are:• at initial installation of the sc
5-2 Magellan® 9500Description of Calibration SequenceThe Calibration Sequence sets the scale to an accurate reference point for weighing. This process
Motion TestProduct Reference Guide 5-3Motion TestThis test verifies that the scale will not ‘zero’ when the weighing surface of the scanner/scale is i
5-4 Magellan® 9500Preparing the Scanner/Scale for Calibration1. Assure that the scanner/scale is stable, secure and properly installed. (Refer to Chap
Calibrating the Scale (Pounds & Kilograms)Product Reference Guide 5-5Figure 5-1. Calibration Access Cover4. Press and release the Calibration Swit
5-6 Magellan® 95008. The Yellow LED will extinguish for approximately 10 seconds and the Remote Display will alternately display and until the scal
Calibration Verification (U.S. Pounds)Product Reference Guide 5-7Calibration Verification (U.S. Pounds)Once you have completed the calibration sequenc
5-8 Magellan® 9500Shift TestThe Shift Test checks to ensure that items placed anywhere on the weigh-ing surface of the scanner/scale are weighed prope
Calibration Verification (U.S. Pounds)Product Reference Guide 5-9Increasing- Load Test (Phase 2)After completing the Shift Test, you must complete the
Product Reference Guide 9DATALOGIC SCANNING, INC. MAGELLAN® END USER LICENSE AGREEMENTNotice to End User: The Datalogic Product you have acquired con
5-10 Magellan® 9500Decreasing-Load TestThis test ensures that the scanner/scale responds properly when a heavy object is followed by a significantly s
Calibration Verification (Kilograms)Product Reference Guide 5-11Calibration Verification (Kilograms)Once you have completed the calibration sequence,
5-12 Magellan® 95008. Place an additional 200 grams on the center of the weighing surface and check that the display reads 1.000 kg. 9. Increase the w
Calibration Verification (Kilograms)Product Reference Guide 5-13Figure 5-3. European Shift Test (Metric)Increasing- Load Test (Phase 2)After completin
5-14 Magellan® 9500Blanking TestThis test ensures that the scanner/scale will indicate its weighing capability has been exceeded if a weight greater t
Calibration Verification (Kilograms)Product Reference Guide 5-15Decreasing-Load TestThis test ensures that the scanner/scale responds properly when a
5-16 Magellan® 9500NOTES
Product Reference Guide 6-1Chapter 6ProgrammingIntroduction to Label ProgrammingThe programming bar code labels contained in this manual will allow yo
6-2 Magellan® 9500Integrating the Scanner With Your Host SystemYour scanner MUST be equipped with the correct hardware (interface board, cable, etc.)
Integrating the Scanner With Your Host Sys-Product Reference Guide 6-3• Interface Related Features — are the mandatory settings necessary to allow com
10 Magellan® 9500ing to Datalogic's standard assistance practices. Datalogic does not warrant that the product will meet End User's requirem
6-4 Magellan® 9500Programming OverviewThe scanner’s programmable feature settings can be modified to accom-modate your system’s unique requirements. T
Programming OverviewProduct Reference Guide 6-5What Is Programming Mode?Programming Mode is a state in which the scanner must be placed in order to ac
6-6 Magellan® 9500Programming SessionA typical programming session is conducted as follows:1. Scan the SWITCH bar code to place the scanner in Program
Programming OverviewProduct Reference Guide 6-73. Scan the SWITCH bar code to save any new settings and exit Pro-gramming Mode. The scanner will sound
6-8 Magellan® 9500Programming SequenceTo modify a scanner feature (item), the programming bar codes contained in this manual must be scanned in a give
Programming OverviewProduct Reference Guide 6-9Table 6-1. Programming Sequence11CAB23123456SETSWITCHENABLENEW FEATUREENABLE NEWFEATUREUSING THEFOLLOWI
6-10 Magellan® 9500LED and Beeper IndicatorsThe scanner provides a set of indicators that verify/announce the various scanner functions. If You Make a
If You Make a Mistake...Product Reference Guide 6-11Test ModeUse this feature to place the scanner into a testing, or “demo” mode. This special mode d
6-12 Magellan® 9500General Scanner and Scale FeaturesDouble Read TimeoutThe Double Read Timeout feature sets a time limit that determines how much tim
General Scanner and Scale FeaturesProduct Reference Guide 6-13Double Read Timeout — continuedRemember to cover any unused bar codes on this and the fa
Product Reference Guide 1-1Chapter 1IntroductionThis Product Reference Guide contains comprehensive instructions on how to install the scanner or scan
6-14 Magellan® 9500Laser TimeoutThe laser timeout feature sets the time for switching the visible laser diodes (VLDs) off if the scanner is idle. Usin
General Scanner and Scale FeaturesProduct Reference Guide 6-15Laser Timeout — continuedRemember to cover any unused bar codes on this and the facing p
6-16 Magellan® 9500Motor TimeoutThe Motor Timeout feature sets the time for automatically switching the motor off when the scanner is not in use. To s
General Scanner and Scale FeaturesProduct Reference Guide 6-17Motor Timeout — continuedRemember to cover any unused bar codes on this and the facing p
6-18 Magellan® 9500Motor Timeout — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only t
General Scanner and Scale FeaturesProduct Reference Guide 6-19Green LED Idle StateThis feature specifies the state of the green scanner LED when the s
6-20 Magellan® 9500Scanner Button OptionsConfigure the scanner volume button to one of the following modes of operation:• Enable all functions: Volume
General Scanner and Scale FeaturesProduct Reference Guide 6-21Scanner Button Options — continuedRemember to cover any unused bar codes on this and the
6-22 Magellan® 9500Power-up Beep ControlSpecifies the type of audible indication that is made when entering scan-ner-active mode on power-up. Choices
General Scanner and Scale FeaturesProduct Reference Guide 6-23Power-up Beep Control — continuedRemember to cover any unused bar codes on this and the
1-2 Magellan® 9500Chapter 6, Programming, details procedures and provides custom bar-codes for setting programmable scanner and scanner/scale features
6-24 Magellan® 9500Good Read Beep ControlThis feature enables/disables scanner beep upon successfully decoding of a label.To set this feature:1. Scan
General Scanner and Scale FeaturesProduct Reference Guide 6-25Good Read Beep FrequencyAdjusts the scanner’s good read beep to sound at low, medium, or
6-26 Magellan® 9500Good Read Beep Frequency — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner r
General Scanner and Scale FeaturesProduct Reference Guide 6-27Good Read Beep LengthSpecifies the duration of a good read beep.To set the good read bee
6-28 Magellan® 9500Good Read Beep VolumeSelects the beeper volume upon a good read beep. There are five selectable volumes, with each volume increment
General Scanner and Scale FeaturesProduct Reference Guide 6-29Good Read Beep Volume — continuedRemember to cover any unused bar codes on this and the
6-30 Magellan® 9500Good Read Beep Volume — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner read
General Scanner and Scale FeaturesProduct Reference Guide 6-31Good Read When to IndicateThis feature specifies when the scanner will provide indicatio
6-32 Magellan® 9500Good Read When to Indicate — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner
General Scanner and Scale FeaturesProduct Reference Guide 6-33Scale EnableUse this feature to enable or disable scale operation.To set this feature:1.
Manual OverviewProduct Reference Guide 1-3Manual Conventions‘NOTE’ blocks contain information that is helpful and rec-ommended. They provide informati
6-34 Magellan® 9500Scale Country ModeWhen a weight is presented, the scanner/scale will apply the country-spe-cific weighing rules specified via this
General Scanner and Scale FeaturesProduct Reference Guide 6-35Scale Country Mode — continuedRemember to cover any unused bar codes on this and the fac
6-36 Magellan® 9500Scale Enforced Zero ReturnThis feature enables/disables the enforced zero return of the scale. Three settings are available for thi
General Scanner and Scale FeaturesProduct Reference Guide 6-37Scale Enforced Zero Return — continuedRemember to cover any unused bar codes on this and
6-38 Magellan® 9500Scale Interface TypeUse this feature to select the scale interface type. Choices are:• No Scale Interface• RS-232 — SASI• RS-232 —
General Scanner and Scale FeaturesProduct Reference Guide 6-39Scale Interface Type — continuedRemember to cover any unused bar codes on this and the f
6-40 Magellan® 9500Scale Motion Level FilterIn environments where checkstands generate excessive vibration, the scale can be set to filter a certain a
General Scanner and Scale FeaturesProduct Reference Guide 6-41Scale Motion Level Filter — continuedRemember to cover any unused bar codes on this and
6-42 Magellan® 9500Scale LED EnableThis feature enables/disables Scale LED (Yellow LED) operation.To set this feature:1. Scan the SWITCH bar code.2. S
General Scanner and Scale FeaturesProduct Reference Guide 6-43Remote Display — Enable/DisableThe scanner-scale can be configured to operate with or wi
1-4 Magellan® 9500Scanner and Scanner/Scale NomenclatureControls, indicators and other nomenclature are shown in Figure 1-1.Figure 1-1. Scanner/Scale
6-44 Magellan® 9500Aux Port ModeSelects the usage for the scanner’s optional auxilliary port. The choices listed below are mutually exclusive (only on
General Scanner and Scale FeaturesProduct Reference Guide 6-45Aux Port Mode — continuedRemember to cover any unused bar codes on this and the facing p
6-46 Magellan® 9500Laser Failure ModeThis configuration item selects whether the scanner should continue oper-ating if only one laser is functional. (
General Scanner and Scale FeaturesProduct Reference Guide 6-47Productivity Index Reporting (PIR)/Cashier Training (CT)When PIR/CT is enabled, label qu
6-48 Magellan® 9500EAS FeaturesEAS ModeThis controls the mode of operation for interfacing with the Sensor-matic® ScanMax ProTM EAS device. Choices ar
EAS FeaturesProduct Reference Guide 6-49EAS Mode — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scan
6-50 Magellan® 9500EAS Mode — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the ba
EAS FeaturesProduct Reference Guide 6-51EAS Beep DurationSets the duration of the EAS successful deactivation beep, specified in 10ms increments. The
6-52 Magellan® 9500EAS Retry CountThis feature sets the number of times the deactivation sequence (defined by the feature, “EAS Deactivation Duration
EAS FeaturesProduct Reference Guide 6-53Manual EAS Deactivation Push ButtonThis feature is for use in Coupled Mode1. When it is enabled, EAS deacti-va
Scanner and Scanner/Scale NomenclatureProduct Reference Guide 1-5ConnectorsThe appearance of the connector panel will vary depending upon the fac-tory
6-54 Magellan® 9500Manual EAS Deactivation Push Button — continuedRemember to cover any unused bar codes on this and the facing page to ensure that th
EAS FeaturesProduct Reference Guide 6-55Manual EAS Deactivation Push Button — continuedRemember to cover any unused bar codes on this and the facing p
6-56 Magellan® 9500EAS Deactivation Duration — CoupledSpecifies the amount of time EAS deactivation is operative once the func-tion has been initiated
EAS FeaturesProduct Reference Guide 6-57EAS Deactivation Duration — RetrySpecifies the amount of time EAS deactivation is operative once the func-tion
6-58 Magellan® 9500EAS Deactivation Duration — ManualSpecifies the amount of time EAS deactivation is operative upon pushing the Manual EAS Deactivati
Interface Related FeaturesProduct Reference Guide 6-59Interface Related FeaturesInterface TypeSpecifies the current scanner interface. Selections are:
6-60 Magellan® 9500Interface Type — continuedTo select the desired interface:1. Disconnect current interface cable(s) if currently connected.2. Scan t
Interface Related FeaturesProduct Reference Guide 6-61RS-232 Interface SelectionRemember to cover any unused bar codes on this and the facing page to
6-62 Magellan® 9500RS-232 Wincor-Nixdorf Interface SelectionRemember to cover any unused bar codes on this and the facing page to ensure that the scan
Interface Related FeaturesProduct Reference Guide 6-63RS-232 Single Cable Interface SelectionRemember to cover any unused bar codes on this and the fa
1-6 Magellan® 9500Physical ParametersThis chapter provides specifications for performance, environmental and electrical parameters. Reference the seco
6-64 Magellan® 9500IBM Port 17 Interface SelectionRemember to cover any unused bar codes on this and the facing page to ensure that the scanner reads
Interface Related FeaturesProduct Reference Guide 6-65IBM USB Interface SelectionRemember to cover any unused bar codes on this and the facing page to
6-66 Magellan® 9500Maximum Host-Transmitted Message LengthSpecifies the maximum number of data characters allowed in messages transmitted to the host.
Interface Related FeaturesProduct Reference Guide 6-67Number of Host Transmission BuffersSpecifies the number of host transmission(s) that may be buff
6-68 Magellan® 9500Global PrefixThis feature applies to RS-232 interfaces (Standard, Wincor-Nixdorf, and Single Cable). It specifies the prefix that i
Interface Related FeaturesProduct Reference Guide 6-69Global Prefix — continuedRemember to cover any unused bar codes on this and the facing page to e
6-70 Magellan® 9500Global SuffixThis feature applies to RS-232 interfaces (Standard, Wincor-Nixdorf, and Single Cable). It specifies the suffix that i
Interface Related FeaturesProduct Reference Guide 6-71Global Suffix — continuedRemember to cover any unused bar codes on this and the facing page to e
6-72 Magellan® 9500IBM FeaturesIBM Interface OptionsIBM interfaces offer specific control over interaction with certain devices. Options for this feat
IBM FeaturesProduct Reference Guide 6-73IBM Scale AddressSpecifies IBM scale address for IBM Port 17. The following three addresses are available:•6A•
Physical ParametersProduct Reference Guide 1-7WeighingSpecifications for scale capacity, settling time, minimum and maximum static weight, zeroing, an
6-74 Magellan® 9500IBM Scale Address — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner reads on
IBM FeaturesProduct Reference Guide 6-75IBM Transmit Labels in Code 39 FormatThis feature enables/disables scanner's ability to set a symbology i
6-76 Magellan® 9500IBM USB Interface OptionsThe IBM-USB interface offers specific control over interaction with cer-tain devices. Options for this fea
IBM FeaturesProduct Reference Guide 6-77IBM USB Interface Options — continuedRemember to cover any unused bar codes on this and the facing page to ens
6-78 Magellan® 9500IBM USB Scanner Device TypeThe IBM-USB protocol allows for the scanner to be identified as one of two different types of barcode sc
RS-232 FeaturesProduct Reference Guide 6-79RS-232 FeaturesRS-232 Baud RateThis feature selects the baud rate required for sending and receiving data.T
6-80 Magellan® 9500RS-232 Baud Rate — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner reads onl
RS-232 FeaturesProduct Reference Guide 6-81RS-232 Baud Rate — continuedRemember to cover any unused bar codes on this and the facing page to ensure th
6-82 Magellan® 9500RS-232 Baud Rate — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner reads onl
RS-232 FeaturesProduct Reference Guide 6-83RS-232 Number of Data BitsSpecifies number of data bits required for sending and receiving data.To set this
Datalogic Scanning, Inc.959 Terry StreetEugene, Oregon 97402Telephone: (541) 683-5700Fax: (541) 345-7140An Unpublished Work - All rights reserved. No
1-8 Magellan® 9500Warm-Up TimeThere are two pertinent warm-up times that apply to the scanner or scan-ner/scale:Thermal EquilibriumWhen the unit is mo
6-84 Magellan® 9500RS-232 Number of Stop BitsSpecifies number of stop bits required for sending and receiving data.To set this feature:1. Scan the SWI
RS-232 FeaturesProduct Reference Guide 6-85RS-232 ParitySpecifies parity required for sending and receiving data.Options for this setting are:• RS-232
6-86 Magellan® 9500RS-232 Parity — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only t
RS-232 FeaturesProduct Reference Guide 6-87RS-232 Hardware ControlEnables/disables use of the RS-232 CTS signal for flow control and/or scan control.O
6-88 Magellan® 9500RS-232 Hardware Control — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner re
RS-232 FeaturesProduct Reference Guide 6-89RS-232 Intercharacter DelaySpecifies delay between the end of one character and the beginning of the next i
6-90 Magellan® 9500RS-232 Software Flow ControlEnables/disables RS-232 Flow Control using XON/ XOFF characters. .To set this feature:1. Scan the SWITC
RS-232 FeaturesProduct Reference Guide 6-91RS-232 Host EchoWhen enabled, this feature passes all data through the scanner to the host as it comes in.
6-92 Magellan® 9500RS-232 Host Echo Quiet IntervalThis setting specifies the time interval of RS-232 channel inactivity which must transpire before th
RS-232 FeaturesProduct Reference Guide 6-93RS-232 Ignore Host CommandsWhen set to ignore host commands, the scanner will ignore all host com-mands exc
Physical ParametersProduct Reference Guide 1-9Figure 1-3. Environmental SpecificationsOperationStorage+40 C +104 F10 C
6-94 Magellan® 9500RS-232 TTLSpecifies whether RS-232 interface provides TTL levels on the output pins TxD and RTS.Choices are:• Normal RS-232 levels•
RS-232 FeaturesProduct Reference Guide 6-95RS-232 TTL InvertEnables/disables inversion of TTL.To set this feature:1. Scan the SWITCH bar code.2. Scan
6-96 Magellan® 9500RS-232 Beep on ASCII BELEnables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCII BEL (07 hex).•Di
RS-232 FeaturesProduct Reference Guide 6-97RS-232 Beep After WeighEnables/disables the ability of the scanner to beep after weight data is transmitted
6-98 Magellan® 9500RS-232 Beep on Not on FileSelect for the host to beep (or not) when a not-on-file condition is detected by the host. This feature i
RS-232 FeaturesProduct Reference Guide 6-99RS-232 ACK NAK EnableThis enables/disables the ability of the scanner to support the RS-232 ACK/NAK protoco
6-100 Magellan® 9500RS-232 ACK NAK Enable — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner rea
RS-232 FeaturesProduct Reference Guide 6-101RS-232 ACK CharacterThis feature specifies which ASCII character will be used as an ACK char-acter.To spec
6-102 Magellan® 9500RS-232 NAK CharacterThis feature specifies which ASCII character will be used as a NAK char-acter.To specify the RS-232 NAK Charac
RS-232 FeaturesProduct Reference Guide 6-103RS-232 Retry on ACK NAK TimeoutThis option specifies the action scanner performs on expiration of the RS-2
1-10 Magellan® 9500Electrical SpecificationsBefore installation, always verify that the site’s electrical service meets the scanner/scale’s requiremen
6-104 Magellan® 9500RS-232 ACK NAK Timeout ValueThis item specifies the time the scanner will wait for an ACK character from the host following a labe
RS-232 FeaturesProduct Reference Guide 6-105RS-232 ACK NAK Retry CountThis feature sets the number of times for the scanner to retry a label trans-mis
6-106 Magellan® 9500RS-232 ACK NAK Error HandlingThis item specifies the method the scanner will use to handle errors detected while waiting to receiv
RS-232 FeaturesProduct Reference Guide 6-107RS-232 ACK NAK Error Handling — continuedRemember to cover any unused bar codes on this and the facing pag
6-108 Magellan® 9500RS-232 Label ID ControlThis feature specifies whether or not Label IDs are transmitted to the host and if so, whether to attach th
RS-232 FeaturesProduct Reference Guide 6-109RS-232 Label ID Control — continuedRemember to cover any unused bar codes on this and the facing page to e
6-110 Magellan® 9500Single Cable RS-232 OptionsThe RS-232 Single Cable interface shares some configuration options with other RS-232 interfaces. Rathe
Single Cable RS-232 OptionsProduct Reference Guide 6-111Single Cable RS-232 Scanner Only ProtocolThis sets the type of interface protocol that will be
6-112 Magellan® 9500Single Cable RS-232 RTS CTS SelectionSpecifies how RTS and CTS are used to control the data flow. RTS is con-trolled by the Scanne
Single Cable RS-232 OptionsProduct Reference Guide 6-113Single Cable RS-232 RTS CTS Selection — continuedRemember to cover any unused bar codes on thi
Laser and Product SafetyProduct Reference Guide 1-11Laser and Product SafetyLaser safety requirements are based on IEC Standard Publication 60825-1 (2
6-114 Magellan® 9500Single Cable RS-232 RTS CTS Selection — continuedRemember to cover any unused bar codes on this and the facing page to ensure that
Single Cable RS-232 OptionsProduct Reference Guide 6-115Single Cable RS-232 Use BCCEnables/disables the ability of the scanner to use BCC.To set this
6-116 Magellan® 9500Single Cable RS-232 Use ACK/NAKEnables/disables the ability of the scanner to use ACK/NAK.To set this feature:1. Scan the SWITCH b
Single Cable RS-232 OptionsProduct Reference Guide 6-117Single Cable RS-232 Use STXEnables/disables the ability of the scanner to use STX.To set this
6-118 Magellan® 9500Set Single Cable RS-232 STX CharacterThis feature selects the STX character.To specify the STX Character:1. Scan the SWITCH bar co
Single Cable RS-232 OptionsProduct Reference Guide 6-119Single Cable RS-232 Use ETXEnables/disables the ability of the scanner to use ETX.To set this
6-120 Magellan® 9500Set Single Cable RS-232 ETX CharacterAllows selection of the ETX character.To specify the ETX Character:1. Scan the SWITCH bar cod
Symbology ProgrammingProduct Reference Guide 6-121Symbology ProgrammingUPC-A EnableEnables/disables the ability of the scanner to decode UPC-A labels.
6-122 Magellan® 9500UPC-A Number System Character TransmissionEnables/disables transmission of a UPC-A number system character. To set this feature:1.
UPC-A EnableProduct Reference Guide 6-123UPC-A Check Character TransmissionEnables/disables transmission of a UPC-A check character.To set this featur
1-12 Magellan® 9500Safety precautions to be taken:This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
6-124 Magellan® 9500Expand UPC-A to EAN-13Enables/disables expansion of UPC-A labels to EAN/JAN-13.To set this feature:1. Scan the SWITCH bar code.2.
UPC-A EnableProduct Reference Guide 6-125UPC/EAN AIM IDThis feature enables/disables transmission of the UPC/EAN AIM symbol-ogy identifier.To set this
6-126 Magellan® 9500UPC-A Label IDThis feature specifies a UPC-A label ID to be added to bar code data.To set this feature:1. Scan the SWITCH bar code
UPC-A EnableProduct Reference Guide 6-127UPC-A 2-Digit Supplemental Label IDThis feature specifies a UPC-A 2-Digit Supplemental label ID to be added t
6-128 Magellan® 9500UPC-A 5-Digit Supplemental Label IDThis feature specifies a UPC-A 5-Digit Supplemental label ID to be added to bar code data.To se
UPC-A EnableProduct Reference Guide 6-129UPC-A 128 Supplemental Label IDThis feature specifies a UPC-A 128 Supplemental label ID to be added to bar co
6-130 Magellan® 9500UPC-E EnableEnables/disables the ability of the scanner to decode UPC-E labels.To set this feature:1. Scan the SWITCH bar code.2.
UPC-E EnableProduct Reference Guide 6-131UPC-E Number System Character TransmissionEnables/disables transmission of a UPC-E number system character.To
6-132 Magellan® 9500UPC-E Check Character TransmissionEnables/disables transmission of a UPC-E check character.To set this feature:1. Scan the SWITCH
UPC-E EnableProduct Reference Guide 6-133Expand UPC-E to UPC-AEnables/disables expansion of UPC-E labels to UPC-A.To set this feature:1. Scan the SWIT
LabelingProduct Reference Guide 1-13LabelingRegulatory, reference and safety labeling is shown in Figure 1-4.Figure 1-4. LabelingOr...Located on EAS S
6-134 Magellan® 9500Expand UPC-E to EAN-13Enables/disables expansion of UPC-E labels to EAN/JAN-13.To set this feature:1. Scan the SWITCH bar code.2.
UPC-E EnableProduct Reference Guide 6-135UPC-E Label IDThis feature specifies a UPC-E label ID to be added to bar code data.To set this feature:1. Sca
6-136 Magellan® 9500UPC-E 2-Digit Supplemental Label IDThis feature specifies a UPC-E 2-Digit Supplemental label ID to be added to bar code data.To se
UPC-E EnableProduct Reference Guide 6-137UPC-E 5-Digit Supplemental Label IDThis feature specifies a UPC-E 5-Digit Supplemental label ID to be added t
6-138 Magellan® 9500UPC-E 128 Supplemental Label IDThis feature specifies a UPC-E 128 Supplemental label ID to be added to bar code data.To set this f
EAN-13 EnableProduct Reference Guide 6-139EAN-13 EnableEnables/disables the ability of the scanner to decode EAN/JAN-13 labels.To set this feature:1.
6-140 Magellan® 9500EAN-13 First Character TransmissionEnables/disables transmission of EAN/JAN-13 first character.To set this feature:1. Scan the SWI
EAN-13 EnableProduct Reference Guide 6-141EAN-13 Check Character TransmissionEnables/disables transmission of an EAN/JAN-13 check character.To set thi
6-142 Magellan® 9500EAN-13 ISBN Conversion EnableEnables/disables conversion of EAN/JAN-13 labels starting with 978 to Bookland ISBN labels.To set thi
EAN-13 EnableProduct Reference Guide 6-143EAN 13 Label IDThis feature specifies an EAN 13 label ID to be added to bar code data.To set this feature:To
1-14 Magellan® 9500Agency CompliancesThe scanner and scanner/scale meets or exceeds the requirements for its device type as set forth by the following
6-144 Magellan® 9500EAN-13 2-Digit Supplemental Label IDThis feature specifies an EAN-13 2-Digit Supplemental label ID to be added to bar code data.To
EAN-13 EnableProduct Reference Guide 6-145EAN-13 5-Digit Supplemental Label IDThis feature specifies an EAN-13 5-Digit Supplemental label ID to be add
6-146 Magellan® 9500EAN-13 128 Supplemental Label IDThis feature specifies an EAN-13 128 Supplemental label ID to be added to bar code data.To set thi
EAN-13 EnableProduct Reference Guide 6-147Bookland AIM IDThis feature enables/disables transmission of the Bookland AIM symbol-ogy identifier.To set t
6-148 Magellan® 9500Bookland Label IDThis feature specifies a Bookland label ID to be added to bar code data.To set this feature:1. Scan the SWITCH ba
EAN-8 EnableProduct Reference Guide 6-149EAN-8 EnableEnables/disables the ability of the scanner to decode EAN/JAN-8 labels.To set this feature:1. Sca
6-150 Magellan® 9500EAN-8 Check Character TransmissionEnables/disables transmission of an EAN/JAN-8 check character.To set this feature:1. Scan the SW
EAN-8 EnableProduct Reference Guide 6-151Expand EAN-8 to EAN-13Enables/disables expansion of EAN/JAN-8 labels to EAN/JAN-13.To set this feature:1. Sca
6-152 Magellan® 9500EAN 8 Label IDThis feature specifies an EAN 8 label ID to be added to bar code data.To set this feature:To set this feature:1. Sca
EAN-8 EnableProduct Reference Guide 6-153EAN-8 2-Digit Supplemental Label IDThis feature specifies an EAN-8 2-Digit Supplemental label ID to be added
Bar Codes SupportedProduct Reference Guide 1-15Bar Codes SupportedThe scanner can read/decode the following bar code types (symbologies):• UPC Version
6-154 Magellan® 9500EAN-8 5-Digit Supplemental Label IDThis feature specifies an EAN-8 5-Digit Supplemental label ID to be added to bar code data.To s
EAN-8 EnableProduct Reference Guide 6-155EAN-8 128 Supplemental Label IDThis feature specifies an EAN-8 128 Supplemental label ID to be added to bar c
6-156 Magellan® 9500EAN-8 Decoding LevelsDecoding levels allow the decoder to be set to perform at one of four selectable levels:• Very Conservative —
EAN-8 EnableProduct Reference Guide 6-157EAN-8 Decoding Levels — continuedRemember to cover any unused bar codes on this and the facing page to ensure
6-158 Magellan® 9500EAN-8 Decoding Levels — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner rea
Other UPC/EAN OptionsProduct Reference Guide 6-159Other UPC/EAN OptionsThe following pages contain other selectable features for UPC/EAN sym-bologies:
6-160 Magellan® 9500UPC/EAN ReconstructionEnables/disables the ability of the scanner to decode a class of UPC/EAN labels with voids. The label voids
Other UPC/EAN OptionsProduct Reference Guide 6-161Price Weight CheckEnables/disables calculation and verification of price/weight check digits. Applie
6-162 Magellan® 9500Price Weight Check — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner reads
Other UPC/EAN OptionsProduct Reference Guide 6-163Price Weight Check — continuedRemember to cover any unused bar codes on this and the facing page to
1-16 Magellan® 9500NOTES
6-164 Magellan® 9500Enable EAN Two LabelEnables/disables the ability of the scanner to decode EAN two-label pairs.To set this feature:1. Scan the SWIT
Other UPC/EAN OptionsProduct Reference Guide 6-165AddonsThe scanner is capable of processing different types of addon codes, including:• 2-Digit Suppl
6-166 Magellan® 9500Addons — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar
Other UPC/EAN OptionsProduct Reference Guide 6-167UPC-A and EAN-13 Decoding LevelsDecoding levels allow the decoder to be set to perform at one of fou
6-168 Magellan® 9500UPC-A and EAN-13 Decoding Levels — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the
Other UPC/EAN OptionsProduct Reference Guide 6-169UPC-A and EAN-13 Decoding Levels — continuedRemember to cover any unused bar codes on this and the f
6-170 Magellan® 9500GTIN EnableEnables/Disables the ability to convert UPCE, UPCA, EAN8, and EAN13 labels into the GTIN 14-character format.To set thi
GTIN EnableProduct Reference Guide 6-171GTIN Label IDThis feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabl
6-172 Magellan® 9500GTIN 2-Digit Supplemental Label IDThis feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enab
GTIN EnableProduct Reference Guide 6-173GTIN 5-Digit Supplemental Label IDThis feature specifies a GTIN label ID to be added to bar code data when GTI
Product Reference Guide 2-1Chapter 2Site Preparation andInstallationThis chapter provides a reference for preparing most checkstands to receive the sc
6-174 Magellan® 9500GTIN Code 128 Supplemental Label IDThis feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is ena
RSS-14 EnableProduct Reference Guide 6-175RSS-14 EnableEnables/disables the ability of the scanner to decode RSS-14 labels.To set this feature:1. Scan
6-176 Magellan® 9500RSS-14 Check Character TransmissionEnables/disables transmission of the RSS-14 check character.To set this feature:1. Scan the SWI
RSS-14 EnableProduct Reference Guide 6-177RSS-14/EAN-128 EmulationEnables/disables the ability of RSS-14 to be transmitted as EAN-128.To set this feat
6-178 Magellan® 9500RSS-14 2D Component EnableWhen this feature is enabled, and the software reads an RSS-14 bar code that has a 2D component associat
RSS-14 EnableProduct Reference Guide 6-179RSS-14 AIM IDThis feature enables/disables transmission of the RSS-14 AIM symbology identifier.To set this f
6-180 Magellan® 9500RSS-14 Label IDThis feature specifies an RSS-14 label ID to be added to bar code data.To set this feature:To set this feature:1. S
RSS Expanded EnableProduct Reference Guide 6-181RSS Expanded EnableEnables/disables the ability of the scanner to decode RSS-Expanded labels.To set th
6-182 Magellan® 9500RSS Expanded EAN-128 EmulationEnables/disables EAN-128 emulation for RSS Expanded.To set this feature:1. Scan the SWITCH bar code.
RSS Expanded EnableProduct Reference Guide 6-183RSS Expanded 2D Component EnableWhen this feature is enabled, and the software reads an RSS Expanded b
Product Reference Guide 1Table of ContentsChapter 1. Introduction ...
2-2 Magellan® 9500Figure 2-1. 9500 ModelsPre-Installation ConsiderationsIt should be noted that the scope of this manual does not encompass all factor
6-184 Magellan® 9500RSS Expanded AIM IDThis feature enables/disables transmission of the RSS Expanded AIM symbology identifier.To set this feature:1.
RSS Expanded EnableProduct Reference Guide 6-185RSS Expanded Label IDThis feature specifies an RSS Expanded label ID to be added to bar code data.To s
6-186 Magellan® 9500RSS Expanded Length ControlThis feature specifies either variable-length or fixed-length decoding for RSS Expanded.To set this fea
RSS Expanded EnableProduct Reference Guide 6-187RSS Expanded Maximum Label LengthThis feature specifies the maximum allowable length of an RSS Expande
6-188 Magellan® 9500RSS Expanded Minimum Label LengthThis feature specifies the minimum allowable length of an RSS Expanded label.To set this feature:
RSS Expanded EnableProduct Reference Guide 6-189RSS Expanded Fixed Length 1This feature specifies RSS Expanded first fixed length.To set this feature:
6-190 Magellan® 9500RSS Expanded Fixed Length 2This feature specifies RSS Expanded second fixed length.To set this feature:1. Scan the SWITCH bar code
Code 39 EnableProduct Reference Guide 6-191Code 39 EnableEnables/disables the ability of the scanner to decode Code 39 labels.To set this feature:1. S
6-192 Magellan® 9500Code 39 Start Stop Character TransmissionEnables/disables transmission of Code 39 start and stop characters.To set this feature:1.
Code 39 EnableProduct Reference Guide 6-193Code 39 Check Character CalculationEnables/disables calculation and verification of an optional Code 39 che
Checkstand DesignProduct Reference Guide 2-3Checkstand Design1. Select a design which allows load-sharing by several muscle groups (for example design
6-194 Magellan® 9500Code 39 Check Character TransmissionEnables/disables transmission of optional Code 39 check character.To set this feature:1. Scan
Code 39 EnableProduct Reference Guide 6-195Code 39 Full ASCIIEnables/disables the ability of the scanner to translate to Code 39 full ASCII labels.To
6-196 Magellan® 9500Code 39 AIM IDThis feature enables/disables transmission of the Code 39 AIM symbology identifier.To set this feature:1. Scan the S
Code 39 EnableProduct Reference Guide 6-197Code 39 Label IDThis feature specifies a Code 39 label ID to be added to bar code data.To set this feature:
6-198 Magellan® 9500Code 39 Length ControlThis feature specifies whether variable-length or fixed-length decoding will be set for Code 39.To set this
Code 39 EnableProduct Reference Guide 6-199Code 39 Maximum Label LengthThis feature specifies the maximum allowable length of a Code 39 label.To set t
6-200 Magellan® 9500Code 39 Minimum Label LengthThis feature specifies the minimum allowable length of a Code 39 label.To set this feature:1. Scan the
Code 39 EnableProduct Reference Guide 6-201Code 39 Fixed Length 1This feature specifies Code 39 first fixed length.To set this feature:1. Scan the SWI
6-202 Magellan® 9500Code 39 Fixed Length 2This feature specifies Code 39 second fixed length.To set this feature:1. Scan the SWITCH bar code.2. Scan t
Code 39 EnableProduct Reference Guide 6-203Code 39 StitchingEnables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presen
2-4 Magellan® 9500Scanner Installation1. Mount the horizontal surface of the scanner flush with the counter-top to encourage slide scanning rather tha
6-204 Magellan® 9500Pharmacode 39 EnableEnables/disables the ability of the scanner to decode Italian Pharmacode 39 labels.To set this feature:1. Scan
Pharmacode 39 EnableProduct Reference Guide 6-205Pharmacode 39 Start Stop Character TransmissionEnables/ disables transmission of start and stop chara
6-206 Magellan® 9500Pharmacode 39 Check Character TransmissionEnables/disables transmission of Pharmacode 39 check character.To set this feature:1. Sc
Pharmacode 39 EnableProduct Reference Guide 6-207Pharmacode 39 Label IDThis feature specifies a Pharmacode 39 label ID to be added to bar code data.To
6-208 Magellan® 9500Code 128 EnableEnables/disables1 the ability of the scanner to decode Code 128 labels.To set this feature:1. Scan the SWITCH bar c
Code 128 EnableProduct Reference Guide 6-209Code 128 Transmit Function CharactersEnables/disables transmission of Code 128 function characters 1, 2, 3
6-210 Magellan® 9500Convert Code 128 to Code 39Enables/disables conversion of Code 128 labels to Code 39.To set this feature:1. Scan the SWITCH bar co
Code 128 EnableProduct Reference Guide 6-211Code 128 AIM IDThis feature enables/disables transmission of the Code 128 AIM symbol-ogy identifier.To set
6-212 Magellan® 9500Code 128 Label IDThis feature specifies a Code 128 label ID to be added to bar code data..To set this feature:1. Scan the SWITCH b
Code 128 EnableProduct Reference Guide 6-213Code 128 Length ControlThis feature specifies whether variable-length or fixed-length decoding will be set
Site Preparation OverviewProduct Reference Guide 2-5Develop a smooth fluid motion during scanning, sharing work equally between hands.Use the entire h
6-214 Magellan® 9500Code 128 Maximum Label LengthThis feature specifies the maximum allowable length of a Code 128 label.To set this feature:1. Scan t
Code 128 EnableProduct Reference Guide 6-215Code 128 Minimum Label LengthThis feature specifies the minimum allowable length of a Code 128 label.To se
6-216 Magellan® 9500Code 128 Fixed Length 1This feature specifies Code 128 first fixed length.To set this feature:1. Scan the SWITCH bar code.2. Scan
Code 128 EnableProduct Reference Guide 6-217Code 128 Fixed Length 2This feature specifies Code 128 second fixed length.To set this feature:1. Scan the
6-218 Magellan® 9500Code 128 StitchingEnables/disables stitching for Code 128 labels. When parts of a Code 128 bar code are presented to the scanner w
EAN-128 EnableProduct Reference Guide 6-219EAN-128 EnableEnables/disables the ability of the scanner to decode EAN-128 labels.To set this feature:1. S
6-220 Magellan® 9500EAN-128 AIM IDThis feature enables/disables transmission of the EAN-128 AIM symbol-ogy identifier.To set this feature:1. Scan the
EAN-128 EnableProduct Reference Guide 6-221EAN-128 Label IDThis feature specifies an EAN-128 label ID to be added to bar code data..To set this featur
6-222 Magellan® 9500Interleaved 2 of 5 (I 2 of 5) EnableEnables/disables the ability of the scanner to decode Interleaved 2 of 5 labels.To set this fe
Interleaved 2 of 5 (I 2 of 5) EnableProduct Reference Guide 6-223I 2 of 5 Check Character CalculationEnables/disables calculation and verification of
2-6 Magellan® 9500Recommended Power Installation: Since the typical grocery envi-ronment includes conveyor belts and electric motors, care should be t
6-224 Magellan® 9500I 2 of 5 Check Character TransmissionEnables/disables transmission of an optional Interleaved 2 of 5 check char-acter.To set this
Interleaved 2 of 5 (I 2 of 5) EnableProduct Reference Guide 6-225I 2 of 5 AIM IDThis feature enables/disables transmission of the I 2 of 5 AIM symbolo
6-226 Magellan® 9500I 2 of 5 Label IDThis feature specifies an I 2 of 5 label ID to be added to bar code data..To set this feature:1. Scan the SWITCH
Interleaved 2 of 5 (I 2 of 5) EnableProduct Reference Guide 6-227I 2 of 5 Length ControlThis feature specifies whether variable-length or fixed-length
6-228 Magellan® 9500I 2 of 5 Maximum Label LengthThis feature specifies the maximum allowable length of an I 2 of 5 label.To set this feature:1. Scan
Interleaved 2 of 5 (I 2 of 5) EnableProduct Reference Guide 6-229I 2 of 5 Minimum Label LengthThis feature specifies the minimum allowable length of a
6-230 Magellan® 9500I 2 of 5 Fixed Length 1This feature specifies I 2 of 5 first fixed length.To set this feature:1. Scan the SWITCH bar code.2. Scan
Interleaved 2 of 5 (I 2 of 5) EnableProduct Reference Guide 6-231I 2 of 5 Fixed Length 2This feature specifies I 2 of 5 second fixed length.To set thi
6-232 Magellan® 9500I 2 of 5 StitchingEnables/disables stitching for I 2 of 5 labels. When parts of an I 2 of 5 bar code are presented to the scanner
Codabar EnableProduct Reference Guide 6-233Codabar EnableEnables/disables the ability of the scanner to decode Codabar labels.To set this feature:1. S
Ventilation and SpacingProduct Reference Guide 2-7Vertical Clearance: Provision must be made to allow adequate space above the scanner bonnet for remo
6-234 Magellan® 9500Codabar Start Stop Character TransmissionEnables/disables transmission of Codabar start and stop characters.To set this feature:1.
Codabar EnableProduct Reference Guide 6-235Codabar Start Stop Character SetThis feature selects the format of transmitted Codabar start/stop charac-te
6-236 Magellan® 9500Codabar Start Stop Character Set — continuedRemember to cover any unused bar codes on this and the facing page to ensure that the
Codabar EnableProduct Reference Guide 6-237Codabar Start Stop Character MatchEnables/disables the requirement that start and stop characters match.To
6-238 Magellan® 9500Codabar Check Character CalculationEnables/disables calculation and verification of an optional Codabar check character.To set thi
Codabar EnableProduct Reference Guide 6-239Codabar Check Character TransmissionEnables/disables transmission of an optional Codabar check character.To
6-240 Magellan® 9500Codabar AIM IDThis feature enables/disables transmission of the Codabar AIM symbology identifier.To set this feature:1. Scan the S
Codabar EnableProduct Reference Guide 6-241Codabar Label IDThis feature specifies a Codabar label ID to e added to bar code data.To set this feature:1
6-242 Magellan® 9500Codabar Length ControlThis feature specifies whether variable-length or fixed-length decoding will be set for Codabar.To set this
Codabar EnableProduct Reference Guide 6-243Codabar Maximum Label LengthThis feature specifies the maximum allowable length of a Codabar label.To set t
2-8 Magellan® 9500• A source of air that provides adequate cooling by convective air flow.If motors, conveyor belts, or other heat producing equipment
6-244 Magellan® 9500Codabar Minimum Label LengthThis feature specifies the minimum allowable length of a Codabar label.To set this feature:1. Scan the
Codabar EnableProduct Reference Guide 6-245Codabar Fixed Length 1This feature specifies Codabar first fixed length.To set this feature:1. Scan the SWI
6-246 Magellan® 9500Codabar Fixed Length 2This feature specifies Codabar second fixed length.To set this feature:1. Scan the SWITCH bar code.2. Scan t
Codabar EnableProduct Reference Guide 6-247Codabar StitchingEnables/disables stitching for Codabar labels. When parts of a Codabar bar code are presen
6-248 Magellan® 9500Code 93 EnableEnables/disables the ability of the scanner to decode Code 93 labels.To set this feature:1. Scan the SWITCH bar code
Code 93 EnableProduct Reference Guide 6-249Code 93 AIM IDThis feature enables/disables transmission of the Code 93 AIM symbology identifier.To set thi
6-250 Magellan® 9500Code 93 Label IDThis feature specifies a Code 93 label ID to be added to bar code data..To set this feature:1. Scan the SWITCH bar
Code 93 EnableProduct Reference Guide 6-251Code 93 Length ControlThis feature specifies whether variable-length or fixed-length decoding will be set f
6-252 Magellan® 9500Code 93 Maximum Label LengthThis feature specifies the maximum allowable length of a Code 93 label.To set this feature:1. Scan the
Code 93 EnableProduct Reference Guide 6-253Code 93 Minimum Label LengthThis feature specifies the minimum allowable length of a Code 93 label.To set t
Service AccessProduct Reference Guide 2-9Service AccessThe scanner and scanner/scale have been engineered to allow performance of all routine service
6-254 Magellan® 9500Code 93 Fixed Length 1This feature specifies Code 93 first fixed length.To set this feature:1. Scan the SWITCH bar code.2. Scan th
Code 93 EnableProduct Reference Guide 6-255Code 93 Fixed Length 2This feature specifies Code 93 second fixed length.To set this feature:1. Scan the SW
6-256 Magellan® 9500Code 93 StitchingEnables/disables stitching for Code 93 labels. When parts of a Code 93 bar code are presented to the scanner with
MSI/Plessey EnableProduct Reference Guide 6-257MSI/Plessey EnableEnables/disables the ability of the scanner to decode MSI/Plessey labels.To set this
6-258 Magellan® 9500MSI/Plessey Check Character CalculationEnables/disables calculation and verification of optional MSI/Plessey check characters.To s
MSI/Plessey EnableProduct Reference Guide 6-259MSI/Plessey Number of Check CharactersSpecifies number of MSI/Plessey check characters to be calculated
6-260 Magellan® 9500MSI/Plessey Check Character TransmissionEnables/disables transmission of optional MSI/Plessey check characters.To set this feature
MSI/Plessey EnableProduct Reference Guide 6-261MSI/Plessey AIM IDThis feature enables/disables transmission of the MSI/Plessey AIM sym-bology identifi
6-262 Magellan® 9500MSI/Plessey Label IDThis feature specifies an MSI/Plessey label ID to be added to bar code data.To set this feature:1. Scan the SW
MSI/Plessey EnableProduct Reference Guide 6-263MSI/Plessey Length ControlThis feature specifies whether variable-length or fixed-length decoding will
2-10 Magellan® 9500Power InstallationReference the wiring diagram in Figure 2-4 for the recommended fusing arrangement.GroundingThe AC/DC Power Supply
6-264 Magellan® 9500MSI/Plessey Maximum Label LengthThis feature specifies the maximum allowable length of an MSI/Plessey label.To set this feature:1.
MSI/Plessey EnableProduct Reference Guide 6-265MSI/Plessey Minimum Label LengthThis feature specifies the minimum allowable length of an MSI/Plessey l
6-266 Magellan® 9500MSI/Plessey Fixed Length 1This feature specifies MSI/Plessey first fixed length.To set this feature:1. Scan the SWITCH bar code.2.
MSI/Plessey EnableProduct Reference Guide 6-267MSI/Plessey Fixed Length 2This feature specifies MSI/Plessey second fixed length.To set this feature:1.
6-268 Magellan® 9500MSI/Plessey StitchingEnables/disables stitching for MSI/Plessey labels. When parts of an MSI/Plessey bar code are presented to the
Standard 2 of 5 EnableProduct Reference Guide 6-269Standard 2 of 5 EnableEnables/disables the ability of the scanner to decode Standard 2 of 5 labels.
6-270 Magellan® 9500Standard 2 of 5 Check Character CalculationEnables/disables calculation and verification of an optional Standard 2 of 5 check char
Standard 2 of 5 EnableProduct Reference Guide 6-271Standard 2 of 5 Check Character TransmissionEnables/disables transmission of an optional Standard 2
6-272 Magellan® 9500Standard 2 of 5 AIM IDThis feature enables/disables transmission of the Standard 2 of 5 AIM symbology identifier.To set this featu
Standard 2 of 5 EnableProduct Reference Guide 6-273Standard 2 of 5 Label IDThis feature specifies an Standard 2 of 5 label ID to be added to bar code
Checkstand PreparationProduct Reference Guide 2-11Checkstand PreparationReference Figure 2-5. When performing a first time installation into a new che
6-274 Magellan® 9500Standard 2 of 5 Length ControlThis feature specifies whether variable-length or fixed-length decoding will be set for Standard 2 o
Standard 2 of 5 EnableProduct Reference Guide 6-275Standard 2 of 5 Maximum Label LengthThis feature specifies the maximum allowable length of a Standa
6-276 Magellan® 9500Standard 2 of 5 Minimum Label LengthThis feature specifies the minimum allowable length of an Standard 2 of 5 label.To set this fe
Standard 2 of 5 EnableProduct Reference Guide 6-277Standard 2 of 5 Fixed Length 1This feature specifies Standard 2 of 5 first fixed length.To set this
6-278 Magellan® 9500Standard 2 of 5 Fixed Length 2This feature specifies Standard 2 of 5 second fixed length.To set this feature:1. Scan the SWITCH ba
Standard 2 of 5 EnableProduct Reference Guide 6-279Standard 2 of 5 StitchingEnables/disables stitching for Standard 2 of 5 labels. When parts of a Sta
6-280 Magellan® 9500NOTES
Product Reference Guide A-1Appendix ALED/Beeper Indications &ControlsFigure A-1 shows the operator’s controls and indicators. The descriptions fol
A-2 Magellan® 9500Controls and IndicatorsThe control panel consists of three indicator LEDs and three push buttons as described in the following pages
Controls and IndicatorsProduct Reference Guide A-3Host DisabledScanner (Green) LED 1-second off, 1/10-second onHost has disabled scanning.Field Replac
2 Magellan® 9500Viewing Angle ... 2-28Placing and In
2-12 Magellan® 9500Liquid Spills and Moisture Select a checkstand design which allows fluids to flow through, and directs liquids away from any electr
A-4 Magellan® 9500Deactivator LEDThe Deactivator LED (tri-color, bottom-most) designates EAS deactiva-tion status (see Table A-2 ). The table also pro
Controls and IndicatorsProduct Reference Guide A-5COUPLED MODE ONLYDeactivation IndicatedDeactivation (Tri-color) LED flashes Red, then Orange, then r
A-6 Magellan® 9500Volume/Tone Push ButtonThe Volume/Tone Push Button also performs multiple functions depend-ing upon the duration of time it is press
Controls and IndicatorsProduct Reference Guide A-7Hold, then release when the beeper soundsIncrements tonePress the push button for approximately 2 se
A-8 Magellan® 9500Manual EAS Deactivation Push ButtonUsing the programming bar codes contained in the Product Refer-ence Guide (PRG) the button can be
Controls and IndicatorsProduct Reference Guide A-9Scale Zero Push ButtonThe Scale Zero Push Button is used for multiple functions as listed in Table A
A-10 Magellan® 9500Calibration SwitchThis switch initiates the scale’s calibration routine. A certified weight set is needed to perform the scale cali
Product Reference Guide B-1Appendix BCable InformationIntroductionThe following pages contain pinout information, enabling you to create standard inte
B-2 Magellan® 9500RS-232 Cable PinoutScannerConnector HardwareRJ45, 10 PositionCable PinoutTable B-1RS-232 Cable PinoutsPIN # FUNCTION DESCRIPTION1 N/
RS-232 Cable Pinout — continuedProduct Reference Guide B-3RS-232 Cable Pinout — continuedScaleConnector HardwareRJ45, 10 PositionCable PinoutTable B-2
Counter CutoutProduct Reference Guide 2-133. Install the AC/DC Power Supply, the Remote Scale Display cable and the interface cable(s) observing the f
B-4 Magellan® 9500IBM Cable PinoutScanner and ScaleConnector HardwareRJ45, 10 PositionCable PinoutTable B-3IBM Cable PinoutsPIN # FUNCTION DESCRIPTION
IBM USB Cable PinoutProduct Reference Guide B-5IBM USB Cable PinoutScanner and ScaleConnector HardwareRJ45, 10 PositionCable PinoutTable B-4IBM USB Ca
B-6 Magellan® 9500Auxilliary PortExternal Handheld InputConnector HardwareRJ45, 10 PositionCable PinoutTable B-5Auxilliary Port Cable PinoutsPIN # FUN
Power CableProduct Reference Guide B-7Power CableConnector Hardware6 pin MolexCable PinoutTable B-6Power Cable PinoutsPIN # FUNCTION DESCRIPTION1 EART
B-8 Magellan® 9500Remote DisplayConnector Hardware4 pin SDLCable PinoutTable B-7Remote Display Cable PinoutsPIN # FUNCTION DESCRIPTION1 +12V OUT +12V
EAS Comm PortProduct Reference Guide B-9EAS Comm PortEAS Deactivator Control Box ConnectionConnector HardwareRJ10Cable PinoutTable B-8EAS Comm Port Ca
B-10 Magellan® 9500NOTES
Product Reference Guide C-1Appendix CKeypadUse the bar codes in this appendix to enter numbers and characters as you would select digits/characters fr
C-2 Magellan® 9500Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad.Scan your sel
Product Reference Guide C-3Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad.Scan
2-14 Magellan® 9500Figure 2-6. Typical Checkstand Design & Cutout LocationOptionalItem DiverterConveyorDeadplateScannerBaggingAreaTake-AwayBeltKey
C-4 Magellan® 9500Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad.Scan your sel
Product Reference Guide C-5Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad.Scan
C-6 Magellan® 9500Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad.Scan your sel
Product Reference Guide C-7Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad.Scan
C-8 Magellan® 9500Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad.Scan your sel
Product Reference Guide D-1Appendix DHost CommandsAccepting Commands from an RS-232 Scanner HostThe scanner responds to the following RS-232 commands:
D-2 Magellan® 9500NOTES
Product Reference Guide E-1Appendix EFactory DefaultsThe following table provides a listing of the most common factory settings for the interfaces sho
E-2 Magellan® 9500Good Read When to Indicate1 (after transmit)1 (after transmit)1 (after transmit)1 (after transmit)1 (after transmit)1 (after transmi
Product Reference Guide E-3EAS Deactivation Duration — Coupled 50 (500ms)50 (500ms)50 (500ms)50 (500ms)50 (500ms)50 (500ms)EAS Deactivation Duration —
Counter CutoutProduct Reference Guide 2-15Refer to Figure 2-7 for dimensional information. Figure 2-8 and Figure 2-9 provide counter cutout details fo
E-4 Magellan® 9500RS-232 Number of Stop Bits0 (1 stop bit)0 (1 stop bit)0 (1 stop bit)0 (1 stop bit)RS-232 Parity 0 (none) 0 (none) 2 (odd) 2 (odd)RS-
Product Reference Guide E-5RS-232 Retry on ACK NAK Timeout1 (enable) 1 (enable) 1 (enable)RS-232 ACK NAK Timeout Value1 (200ms) 1 (200ms) 1 (200ms)RS-
E-6 Magellan® 9500UPC-A Number Sys-tem Character Trans-mission0 (disable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable)UPC-A Check Char-acter
Product Reference Guide E-7UPC-E 128 Supple-mental Label ID4500("E") 4500("E") 4300("C") 4500("E")EAN-13 Enabl
E-8 Magellan® 9500EAN-8 128 Supple-mental Label ID4646 ("FF")4646 ("FF")4200 ("B")4646 ("FF")EAN-8 Decoding Le
Product Reference Guide E-9RSS-14 Label ID5234 ("R4")5234 ("R4")4500 ("E")5234 ("R4")RSS Expanded Enable0 (dis
E-10 Magellan® 9500Code 39 Full ASCII 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable)Code 39 AIM ID 0 (disable) 0 (disable) 0
Product Reference Guide E-11Code 128 AIM ID 0 (disable) 0 (disable) 0 (disable)Code 128 Label ID 2300 ("#") 2300 ("#") 4B00 ("
E-12 Magellan® 9500I 2 of 5 Maximum Label Length50 50 50 50 50 50I 2 of 5 Minimum Label Length666666I 2 of 5 Fixed Length 110 10 10 10 10 10I 2 of 5 F
Product Reference Guide E-13Codabar Fixed Length 1888888Codabar Fixed Length 214 14 14 14 14 14Codabar Stitching 0 (disable) 0 (disable) 0 (disable) 0
2-16 Magellan® 9500Figure 2-8. Cutout Dimensions: Recommended for 8500/9500 Interchangeability20.125"(51.12cm)0.75"(1.9cm)18.625"(47.30
E-14 Magellan® 9500MSI/Plessey Label ID4000 ("@")4000 ("@")4F00 ("O")4000 ("@")MSI/Plessey Length Control0(var
Product Reference Guide E-15Standard 2 of 5 Mini-mum Label Length666666Standard 2 of 5 Fixed Length 110 10 10 10 10 10Standard 2 of 5 Fixed Length 200
E-16 Magellan® 9500NOTES
Product Reference Guide F-1Appendix FHandheld Data FormatRequirementsThis appendix provides application notes to describe the general format of data t
F-2 Magellan® 9500Datalogic Handheld Data Format RequirementsThe following sections describe label transmission formats that are typi-cally observed i
Product Reference Guide F-3UPC-A with 5-Digit Supplemental• Number system must be included in label data• Check digit must be included in label data a
F-4 Magellan® 9500UPC-E with 2-Digit Supplemental• Number system must be included in label data.• Check digit must be included in label data and is as
Product Reference Guide F-5EAN-8• Check digit must be included in label data and is assumed to be cor-rect• Prefix must be an ASCII characters 'F
F-6 Magellan® 9500EAN-13• Check digit must be included in label data and is assumed to be cor-rect• Prefix must be an ASCII character 'F'- t
Product Reference Guide F-7Code 39• Check character must be included in label data.• Label length including start, stop and check characters and exclu
Counter CutoutProduct Reference Guide 2-17Figure 2-9. Cutout Dimensions: Minimum Required Counter Cutout20.09 ± 0.06"(51.03 ± 0.15cm)1.22"(3
F-8 Magellan® 9500Codabar• Check character must be included in label data.• Label length including check character and excluding prefix charac-ter mus
Product Reference Guide F-9MSI/Plessey• Check character must be included in label data.• Label length including check character and excluding prefix c
F-10 Magellan® 9500AIM FormatsAIM specifies a 3-character string that is attached as a prefix to the label data for transmission. Because AIM specifie
Product Reference Guide F-112-Digit Supplemental• Supplemental data is appended to any EAN base label.• Prefix must be ASCII characters ']E1&apos
F-12 Magellan® 9500Code 128 Supplemental• Supplemental data is appended to any EAN base label.• Prefix must be ASCII characters ']C0'.• leng
Product Reference Guide F-13Codabar• Check character must be included in label data.• Label length including check character and excluding prefix char
F-14 Magellan® 9500RSS-14• Prefix must be ASCII characters ']e0'.• Check character must be included in label.• Label length excluding prefix
Product Reference Guide F-15Code 128 / EAN128• Prefix must be either ASCII characters ']C0', ']C1' or ']C2'.• Label leng
F-16 Magellan® 9500NOTES
ASCII Character SetThe table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed
2-18 Magellan® 9500Checkstand MountingThere are a number of things to take into account when installing the unit into a checkstand. Key factors are er
AustraliaDatalogic Scanning Pty LtdTelephone: [61] (2) 9870 [email protected] and BeneluxDatalogic Scanning SarlTelephone: [3
Installation OverviewProduct Reference Guide 2-19The following text describes each of these steps.UnpackingTo unpack the unit:• Inspect the package fo
2-20 Magellan® 9500Figure 2-10. Remove Protective Vinyl• Proceed to the Operational Verification instructions below.Operational VerificationFollow the
Installation OverviewProduct Reference Guide 2-21When power is applied to the unit, the normal indicator sequence is:• The scanner indicator (top-most
Product Reference Guide 3Shift Test (Metric) ... 5-12Incr
2-22 Magellan® 9500Scanner: Pass UPC/EAN bar code labels in front of the scanner’s win-dows. Since the interface cable is not yet connected to the POS
Installation OverviewProduct Reference Guide 2-23Scale: If the Yellow (middle, scale) LED is not lit, press the Scale Zero Push Button momentarily. If
2-24 Magellan® 9500Diagnostic ModesTwo diagnostic modes are available which allow you to initiate scanner or scale diagnostic tests, as well as verify
Installation OverviewProduct Reference Guide 2-25Scale Diagnostic ModeTo enter Scale Diagnostic Mode, press the Scale Zero Push Button for approximate
2-26 Magellan® 9500Figure 2-11. Cable RoutingScannerAC PowerSwitch(recommended)AC/DCPowerSupplyEAS Controller BoxAC PowerEAS Interface CableScannerInt
Remote Scale Display Placement/InstallationProduct Reference Guide 2-27Figure 2-12 provides physical dimensions for the AC/DC Adapter (part number 8-0
2-28 Magellan® 9500Viewing AngleThe optimum viewing angle is directly facing the customer. To ensure that the display is easily readable for the major
Remote Scale Display Placement/InstallationProduct Reference Guide 2-29Placing and Installing the Remote Scale Display(Short Pedestal Base ONLY)1. Det
2-30 Magellan® 9500Figure 2-14. Physical Measurements: Remote Display (Short Base)6. Cut the stalk to fit your installation (if required).7. Route the
Remote Scale Display Placement/InstallationProduct Reference Guide 2-3111. Install mounting screws or bolts to complete the installation of the Remote
4 Magellan® 9500EAS Deactivation Duration — Retry ... 6-57EAS Deactivation Duratio
2-32 Magellan® 9500Figure 2-16. Remote Scale Short Base Display Mounting TemplateChanging Weighing ModesYour scanner/scale has been programmed for wei
Set-Up & InstallationProduct Reference Guide 2-33Set-Up & InstallationThese setup and installation procedures assume that you have already pre
2-34 Magellan® 9500Swapping Position: EAS Single-Antenna ONLYThe EAS Antenna must be located in the position needed for your instal-lation. Reference
Set-Up & InstallationProduct Reference Guide 2-354. Disconnect the Load Cell harness.5. Move the Load Cell/Spider Assembly into position on the op
2-36 Magellan® 9500Set-up1. Place the scanner on the checkstand next to the counter cutout.2. Make all connections to peripheral devices, such as the
Set-Up & InstallationProduct Reference Guide 2-37Figure 2-21. Connecting Cables to the Scanner/ScalePOS TERMINAL REMOTE DISPLAY AUXILLIARY PORT SC
2-38 Magellan® 9500Installation1. Make sure that all cables are firmly attached (except that the AC/DC power supply should not be connected to the AC
Set-Up & InstallationProduct Reference Guide 2-393. Hook the fingers of both hands into the lift handles. The first is located along the inside of
2-40 Magellan® 9500Figure 2-23. Using the Lift HandlesMarked"Lift Handle"DO NOT use theEAS Antenna to lift the unit
System Power-Up RecapProduct Reference Guide 2-41System Power-Up RecapThe System Power-Up procedure may vary depending upon the require-ments of your
Product Reference Guide 5UPC-A Enable ... 6-121
2-42 Magellan® 95006. Power-up the scanner or scanner/scale by connecting the power cord to an AC power outlet. Wait for the unit to complete the Self
Product Reference Guide 3-1Chapter 3Operation andMaintenanceThe information contained in this chapter describes how to operate and maintain the scanne
3-2 Magellan® 9500Figure 3-1. Scan ZoneProper Scanning TechniqueThe scanner was designed to provide the ultimate in ergonomic enhance-ments for Point-
Product Reference Guide 3-3Deactivating Security LabelsSensormatic® Ultra-Max®, Ultra-Strip® II and III EAS (Electronic Arti-cle Surveillance) tags ca
3-4 Magellan® 9500EAS Deactivation IndicatorsThe scanner can be programmed to beep in acknowledgement of deactiva-tion or upon deactivation failure. A
Product Reference Guide 3-5Proper Weighing Technique1. The L-shaped All-Weighs™ platter allows you to place items any-where on its surface, including
3-6 Magellan® 9500Operational ControlsThe function of scanner and scale controls and indicators is listed in Appendix A, LED/Beeper Indications &
Operational ModesProduct Reference Guide 3-7Error ReportingIf a fatal error is detected during Selftest or operation, the unit will not advance to Nor
3-8 Magellan® 9500• When the scanner or scanner/scale completes its Selftest successfully, it emits a tone (when configured to do so) and enters Opera
Additional FunctionsProduct Reference Guide 3-9Sleep Mode After the scanner has been left idle for a preset period of time, the laser and/or motor aut
6 Magellan® 9500RSS-14 Check Character Transmission ... 6-176RSS-14/EAN-128 Emulation .
3-10 Magellan® 9500Pressing and holding the Volume/Tone Push Button for approximately eight seconds initiates a reset, which is sounded by a rapid num
Additional FunctionsProduct Reference Guide 3-11Calibrating the ScaleThe second adjustment, calibration, defines and sets a standard reference weight
3-12 Magellan® 9500Operational MaintenanceThe scanner or scanner/scale will provide dependable service for many years. The following maintenance proce
Operational MaintenanceProduct Reference Guide 3-13Vertical Scan Window ReplacementThe Vertical Scan Window enclosed in the All Weighs™ Platter is a r
3-14 Magellan® 95003. The vertical scan window is held in place by two tabs each on its top and bottom edges. To remove it, carefully push out on the
Operational MaintenanceProduct Reference Guide 3-15Horizontal Scan Window Replacement (WRG)Wear Resistant Glass (WRG) horizontal scan windows are repl
3-16 Magellan® 9500Figure 3-5. Removing/Replacing the WRG WindowSlide WRGWindow OutRemoveVertical Bezel
Product Reference Guide 4-1Chapter 4Problem IsolationIn the event of a suspected functional problem, use the troubleshooting references provided in th
4-2 Magellan® 9500Operational TestsThese are the tests that run continually during Normal Operation and Sleep Mode. Firmware checks all subsystems, ac
Error CodesProduct Reference Guide 4-3Error CodesIf an error is detected, the scanner will sound a long low tone (for one sec-ond) and alternately fla
Product Reference Guide 7I 2 of 5 Check Character Transmission ... 6-224I 2 of 5 AIM ID
4-4 Magellan® 9500Error CodeProbable Cause Corrective Action0BlinkingConfigurationNo POS interface has been selected (Null interface). See the topic,
Scale Error ReportingProduct Reference Guide 4-5Figure 4-1. 7-Segment LED DisplayScale Error ReportingScale diagnostics uses the Remote Scale Display
4-6 Magellan® 9500FlowchartsThe problem isolation flowcharts on the following pages allow you to identify and troubleshoot problems with your system.E
FlowchartsProduct Reference Guide 4-7Figure 4-2. Problem Isolation: StartSTARTYESNODoesthe scannerpower-up?YESNODoesthe scannerpass Selftest?YESNOIs t
4-8 Magellan® 9500Figure 4-3. Problem Isolation: SelftestCall Tech SupportCall Tech SupportError code 4. indicates a failed horizontal VLDM (laser) as
FlowchartsProduct Reference Guide 4-9Figure 4-4. Problem Isolation: Poor/No ReadingDONEDONEPOOR/NO READINGSTARTHave you verified thatall scan windows
4-10 Magellan® 9500Figure 4-5. Problem Isolation: No Transmit to POSDONEDONENO TRANSMIT TO POSSTARTVerify programmable parameters using the informatio
FlowchartsProduct Reference Guide 4-11Figure 4-6. Problem Isolation: ScaleSCALE STARTView the Remote Display and/or the Yellow scale status LED for th
4-12 Magellan® 9500Figure 4-7. Problem Isolation: Remote DisplayCall Tech SupportDONEDONEREMOTE DISPLAYSTARTYESYESYESYESNONONONOIs theunit configuredf
FlowchartsProduct Reference Guide 4-13Figure 4-8. Problem Isolation: EAS SystemDONEDONENO EAS DEACTIVATIONSTARTVerify programmable parameters using th
Comentarios a estos manuales