DEFAULT VALUES
USB-KBD DEFAULT SETTINGS
USA keyboard, FIFO enabled, inter-character and inter-code delays disabled, USB
keyboard speed normal.
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = ENTER, character replacement disabled.
RS-232 Standard DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled, rx timeout
5 sec., ack/nack disabled, FIFO enabled, inter-character delay disabled, serial trigger
lock disabled.
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = CR-LF, character replacement disabled.
WEDGE DEFAULT SETTINGS
USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock
unchanged, inter-character and inter-code delays disabled, control character
emulation = ctrl+shift+key.
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = ENTER, character replacement disable.
PEN DEFAULT SETTINGS
interpret operating mode, conversion to code 39 disabled, output level normal, idle
level normal, minimum output pulse 600 μs, overflow medium, inter-block delay
disabled.
CODE SELECTION
Enabled codes
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
Interleaved 2/5
check digit control and transmission, variable length code; 4-99 characters
Standard Code 39
no check digit control, variable length code; 1-99 characters
Code 128
variable length code; 1-99 characters
Disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI, Code 11,
Code 16K, Code 49, GS1 DataBar™ Codes
TECHNICAL FEATURES
PowerScan
D8330/ D8330 AR
Electrical Features PowerScan™ D8330
PowerScan™ D8330
AR
Power Supply
4 to 30 VDC
Max. Consumption: 0.076 mm (3 mils) 0.25 mm (10 mils)
@ 4V
@5V
@30V
Sleep mode
420 mA
310 mA
62 mA
4 mA
500 mA
370 mA
70 mA
4 mA
Scan Rat 35 ± 5 scans/sec
Reading Indicators
Good Read LED (green)
Good Read Spot (green), Beeper
Optical Features
Reading Field
(Typical performance at 20ºC / 68ºF
on high quality barcodes)
110 cm (43.3 in)
@ 55 mils
1090 cm (429.13 in)
@ 100 mils reflective
Max. Resolution 0.076 mm (3 mils) 0.178 (7,5 mils)
PCS (Datalogic Test Chart) 15% 25%
Laser Features
Power (max) 0.9 mW 1.3 mW
Scan Angle 42° 13.5° ± 0.7
Laser Safety Class Class 2 EN 60825-1/CDRH
Environmental Features
Working Temperature -30 °C to + 50 °C / -22° to +122 °F
Storage Temperature -30 °C to + 70 °C / -22° to +158 °F
Humidity 90% non condensing
Drop Resistance IEC 68-2-32 Test ED 2 m
Protection Class IP65
Mechanical Features
Weight (without cable) about 295 g (10.4 oz)
Cable Length 2 m (6 ft 6 in)
RESTORE DEFAULT
RESTORE DEFAULT
Ì$+$*oÎ
To change the defaults refer to the PowerScan™ D8330/M8330 Reference Manual, or to
the Datalogic Aladdin™ Configuration program, both downloadable from the website.
INTERFACE SELECTION
Select one of the interface codes according to your application.
USB INTERFACE SELECTION
* When configuring USB-COM, the relevant files and drivers must be installed from the
USB Device Installation software, which can be downloaded from the web site http://
www.scanning.datalogic.com.
PEN EMULATION INTERFACE SELECTION
RS-232 INTERFACE SELECTION
WEDGE INTERFACE SELECTION
Interface for IBM XT and IBM Terminals 3151, 347X and 348X can be selected from the
PowerScan D8330/M8300 Reference Manual available online at http://www.scanning.dat-
alogic.com.
USB-KBD
Ì$+UA03$-:Î
USB-KBD-ALT-MODE
Ì$+UA04$-@Î
USB-COM*
Ì$+UA02$-4Î
USB-IBM-Hand Held
Ì$+UA01$-.Î
USB-IBM Table top
Ì$+UA00$-(Î
USB KBD-APPLE
Ì$+UA05$-FÎ
PEN
Ì$+CP6$-BÎ
RS-232 Standard
Ì$+CP0$-$Î
Nixdorf Mode A
Ì$+CM2EC0$->Î
Fujitsu
Ì$+CM1$-ÈÎ
ICL Mode
Ì$+CM0$-ÃÎ
Wedge IBM AT or PS/2 PCs
Ì$+CP500$-aÎ
PC Notebook
Ì$+CP505$-ÈÎ
PC Notebook - ALT mode
Ì$+CP508$-2Î
IBM AT - ALT mode
Ì$+CP507$-+Î
KEYBOARD NATIONALITY
USB-KBD and Wedge users should select one of the following wedge keyboard nationality
codes according to the keyboard.
The following Keyboard Nationality selections are only valid for IBM AT compatible PCs:
Belge
Ì$+FJ7$-8Î
Deutsch
Ì$+FJ3$-$Î
English
Ì$+FJ4$-)Î
Español
Ì$+FJ6$-3Î
Français
Ì$+FJ2$-ÊÎ
Italiano
Ì$+FJ1$-ÅÎ
Svenskt
Ì$+FJ5$-.Î
USA (Default)
Ì$+FJ0$-|Î
Japanese
Ì$+FJ8$-=Î
Russian (Latin)
Ì$+FJ9$-BÎ
Russian (Cyrillic)
Ì$+FJA$-jÎ
Hungarian
Ì$+FJB$-oÎ
Slovenian, Croatian, Serbian (Latin)
Ì$+FJC$-tÎ
Romanian
Ì$+FJD$-yÎ
Czech Republic
Ì$+FJE$-~Î
USING POWERSCAN™ D8330/D8330 AR READERS
PowerScan™ D8330 readers automatically scan barcodes at a distance. Simply aim and
pull the trigger. Code scanning is performed along the scan line emitted from the reading
window. This line must cross the entire code. The best reading angles are indicated in the
figure below.:
AIMING SYSTEM
PowerScan™ D8330 and PowerScan™ D8330 AR provide an aiming system. If enabled, a
partial trigger press produces a red spot, which should be aimed over the code center to
get the best reading performance, see figure (1) above. By completely pressing the trigger
the scan line appears to start code scanning (2) .
After setting up the reader
, you can enable or disable the aiming system by reading the
codes below:
Disable Aiming System (Default)
Ì$+Bj0$-"Î
Enable Aiming System
Ì$+Bj1$-'Î
DATA FORMAT TERMINATORS
For your convenience, some common Terminators are given below. For other Header/
Terminator selections, Data Format and Advanced Data Format parameters, see the
PowerScan™ D8330/M8330 Reference Manual.
OPERATING TEST
Read the TEST code below.
Code 128
CR-LF
Ì$+EA120D0A$-ÃÎ
Enter
Ì$+EA1183$-0Î
Tab
Ì$+EA1184$-8Î
None
Ì$+EA10$-dÎ
test