Symbologies
228 PowerScan
TM
PD7100 Corded
Codabar — cont.
Codabar Check Character Calculation
Enable this option to enables/disables calculation and verification of an optional
Codabar check character. When disabled, any check character in the label is treated as a
data character
ENTER/EXIT PROGRAMMING MODE
Codabar Check Character Calculation = Don’t Calculate
Codabar Check Character Calculation = Enable AIM standard
check char.
Codabar Check Character Calculation = Enable Modulo 10
check char.
DEFAULT
Vista de pagina 237