CBX ELECTRICAL CONNECTIONS
67
4
4.7 ON-BOARD ETHERNET INTERFACE
The on-board Ethernet Interface can be used for TCP/IP communication with a remote or
local host computer by connecting the reader to either a LAN or directly to a host PC. There
is no need to use a crossover adapter since Matrix 300™ incorporates an auto-cross
function.
A CAB-ETH-M0x cable can be used to connect to a LAN.
On the Matrix 300™ Ethernet interface the following communication channels are available:
Data Socket
Image Socket
WebSentinel Socket
Image FTP Client
HTTP Server
EtherNet/IP
Profinet IO
Modbus TCP
For further details refer to the Ethernet Folder in the VisiSet™ Help On Line and to the
"Matrix Ethernet Service Guide.pdf" document provided as supplementary documentation.
4.8 USER INTERFACE - SERIAL HOST
The following table contains the pinout for standard RS232 PC Host interface. For other user
interface types please refer to their own manual.
RS232 PC-side connections
1
5
9
6
9-pin male connector
13
25
14
1
25-pin male connector
Pin
Name
Pin
Name
2
RX
3
RX
3
TX
2
TX
5
GND
7
GND
7
RTS
4
RTS
8
CTS
5
CTS