Datalogic Rhino-NET 40012 Manual de usuario Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 49
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
INSTALLATION
17
2
2.6 CONNECT POWER CABLE
1. Turn the RHINO™ off before attaching the power plug.
2. Connect the power cable to vehicle power (See the following section titled “Vehicle 11-
75VDC Direct Connection.”) or to an AC adapter.
3. Connect power by inserting the power plug into the power connector on the bottom of the
RHINO™.
4. Both the plug and receptacle are keyed and care must be used when connecting the
power cable. Twist the nut of the power plug clockwise until tight.
Figure 22 - Connect Power Cable to RHINO™
5. Turn the RHINO™ on.
2.7 VEHICLE 11-75 VDC DIRECT CONNECTION
CAUTION
For proper and safe installation, the input power cable must be connected
to a fused circuit on the vehicle. This fused circuit requires a 5 Amp
maximum time delay (slow blow) high interrupting rating fuse. If the supply
connection is made directly to the battery, the fuse should be installed in
the positive lead within 5 inches of the battery positive (+) terminal.
CAUTION
For installation by trained service personnel only
WARNING
Risk of ignition or explosion. Explosive gas mixture may be vented from
battery. Work only in well-ventilated area. Avoid creating arcs and sparks at
battery terminals.
Vista de pagina 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 48 49

Comentarios a estos manuales

Sin comentarios