INSTALLATION
9
2
For this interface type, the Multidrop Address must also be set via serial channel by
the WinHost utility or by ESC sequences.
Figure 7 shows an example of a multidrop configuration between a Multiplexer and
DS1100 scanners.
max 2 m
DS1100
# x
(up to 31)
DS1100
# 1
DS1100
# 0
RTX485 +
RTX485 -
RTX485 -
RTX485 +
Three wires +
shield
120 Ohm
120 Ohm
SGND
max 1200 m
RS485 REF
SHIELD
MULTIPLEXER
Figure 7 - DS1100 Multidrop connection to a Multiplexer