READING FEATURES
19
3
For example, the DS1100 (350 scans/sec.) for a 25 mm high code moving at 500
mm/s performs:
[(25/500)
*
350] - 2 = 15 effective scans.
3.2 PICKET-FENCE MODE
Figure 19 - "Picket-fence" scanning mode
If scanning is parallel to the code motion, (Figure 19), the number of effective scans
is given by:
SN = [((FW-LW)/LS)
*
SS] -2
These symbols signify:
SN = number of effective scans
FW = reading field width (in mm)
LW = label width (in mm)
LS = label movement speed (in mm/s)
SS = scans per second
For example, for a 50 mm wide code moving in a point where the reading field is 180
mm wide at a 1300 mm/s speed, the DS1100 (350 scans per sec.), performs:
[((180-50)/1300)
*
350] - 2 = 33 scans