Datalogic DS2200 Manual de instrucciones

Busca en linea o descarga Manual de instrucciones para Lectores De Códigos De Barras Datalogic DS2200. Datalogic DS2200 Instruction manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Reference Manual

www.automation.datalogic.comDS2200Reference Manual

Pagina 2

GUIDE TO INSTALLATION The following can be used as a checklist to verify all the necessary steps for complete installation of the DS2200 scanner.

Pagina 3 - CONTENTS

INTRODUCTION 1 1 INTRODUCTION 1.1 PRODUCT DESCRIPTION The DS2200 scanner is a cost effective barcode reader complete with decoder designed to sati

Pagina 4

DS2200 1 A security system allows the laser to activate only once the motor has reached the correct rotational speed; consequently, the laser beam is

Pagina 5 - REFERENCES

INTRODUCTION 1 The following models are therefore available: DS2200 - X X X X Optical Resolution 1 = Standard Resolution 2 = High Resolution Readi

Pagina 6 - SAFETY PRECAUTIONS

DS2200 2 2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the DS2200 reader and all the parts supplied with the equipment are present and intact whe

Pagina 7 - POWER SUPPLY

INSTALLATION 2 2.2 MECHANICAL INSTALLATION DS2200 can be installed to operate in any position. There are three screw holes (M2.5 x 5) on the body of

Pagina 8 - FCC COMPLIANCE

DS2200 2 2.2.1 Mounting DS2200 Using the DS2200 mounting bracket you can obtain the most suitable position for the reader as shown in the figure belo

Pagina 9 - GENERAL VIEW

INSTALLATION 2 2.3 ELECTRICAL CONNECTIONS The DS2200 cable is equipped with a 25-pin female D-sub connector for connection with the power supply and

Pagina 10 - GUIDE TO INSTALLATION

DS2200 2 2.3.1 Power Supply The following pins of the DS2200 connector are used: 13/9251VSGNDCHASSISUSER INTERFACEGNDV+ (5 Vdc)DS2200 Figure 4 - Pow

Pagina 11 - 1 INTRODUCTION

INSTALLATION 2 The following figure shows an example of a multidrop configuration between a Multiplexer and DS2200 scanners. 120 Ohmmax. 1200 m.RTX48

Pagina 12 - 1.2 MODEL DESCRIPTION

Datalogic Automation Srl Via S. Vitalino, 13 40012 - Lippo di Calderara di Reno Bologna - Italy DS2200 Reference Manual Ed.: 08/2008

Pagina 13 - DS2200 - X X X X

DS2200 2 7SGNDSGNDTXDRXAUX3RXDTXAUX2USER INTERFACEDS2200 Figure 7 - RS232 auxiliary interface connections 2.3.4 Inputs The inputs available on the

Pagina 14 - 2 INSTALLATION

INSTALLATION 2 2.3.5 Outputs Two general purpose outputs are available. These outputs can only be connected as open collector configurations. The fol

Pagina 15 - 2.2 MECHANICAL INSTALLATION

DS2200 2 2.4 USER INTERFACE The following table contains the pinout for standard RS232 PC Host interface. For other user interface types, please refe

Pagina 16 - 2.2.1 Mounting DS2200

INSTALLATION 2 2.5 POSITIONING The DS2200 scanner is able to decode barcode labels at a variety of angles, however significant angular distortion may

Pagina 17 - 2.3 ELECTRICAL CONNECTIONS

DS2200 2 The Tilt angle is represented by the value T in Figure 12. Position the reader in order to minimize the Tilt angle. TFigure 12 - Tilt angle

Pagina 18 - 2.3.1 Power Supply

INSTALLATION 2 2.6 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations. Dotted lines in the figures refer to option

Pagina 19 - INSTALLATION

DS2200 2 The Master scanner is also connected to the Host on the RS232 auxiliary serial interface. The External Trigger signal is unique to the syste

Pagina 20 - 2.3.4 Inputs

INSTALLATION 2 2.6.3 Multiplexer Each scanner is connected to a Multiplexer (for example MX4000) with the RS485 half-duplex main interface. 123RS48

Pagina 21 - 2.3.5 Outputs

DS2200 3 3 READING FEATURES The number of scans performed on the code by the DS2200 and therefore the decoding capability is influenced by the follo

Pagina 22 - 2.4 USER INTERFACE

READING FEATURES 3 For example, the DS2200 (500 scans/sec.) for a 25 mm high code moving at 500 mm/s performs: [(25/500) * 500] - 2 = 23 effective sca

Pagina 23 - Figure 11 - Skew angle

CONTENTS REFERENCES ... v Conventions...

Pagina 24 - Figure 12 - Tilt angle

DS2200 3 3.3 PERFORMANCE The DS2200 scanner is available in different versions according to the reading performance. Version Max Code Resolution S

Pagina 25 - 2.6.2 RS485 Master/Slave

READING FEATURES 3 3.4 READING DIAGRAMS The following diagrams show the reading distance for barcodes with different densities. DS2200-1XXX (Standar

Pagina 26

DS2200 3 DS2200-2XXX (High Resolution) 10212(in)01 53(in)2401020304050 6070 8090100110120130(mm)6050403020100102030405060(mm)0.10 mm(4 mils)0.12 mm(5

Pagina 27 - 2.6.3 Multiplexer

MAINTENANCE 4 4 MAINTENANCE 4.1 CLEANING Clean the windows periodically for continued correct operation of the reader. Dust, dirt, etc. on the win

Pagina 28 - 3 READING FEATURES

DS2200 5 5 TECHNICAL FEATURES DS2200-1XXX DS2200-2XXX ELECTRICAL FEATURES Power Maximum input voltage 5 Vdc Consumption 0.4 A; 2 W max. Seri

Pagina 29 - 3.2 PICKET-FENCE MODE

TECHNICAL FEATURES 5 SOFTWARE FEATURES READABLE CODE SYMBOLOGIES • EAN/UPC (including Add-on 2 and Add-on 5) • Code 93 • 2/5 Interleaved • Code

Pagina 30 - 3.3.1 Raster

GLOSSARY Aperture Term used on the required CDRH warning labels to describe the laser exit window. Barcode A pattern of variable-width bars and sp

Pagina 31 - 3.4 READING DIAGRAMS

EEPROM Electrically Erasable Programmable Read-Only Memory. An on-board non-volatile memory chip. Full Duplex Simultaneous, two-way, independent tra

Pagina 32

Protocol A formal set of conventions governing the formatting and relative timing of message exchange between two communicating systems. Raster The

Pagina 33 - WARNING

Tilt Rotation around the Z axis. Used to describe the position of the barcode with respect to the laser scan line. See pars. 2.2.1 and 2.5. Trigger

Pagina 34 - 5 TECHNICAL FEATURES

3.3.1 Raster ... 20 3.4 Reading Diagrams ...

Pagina 35 - PHYSICAL FEATURES

INDEX A Accessories; 3 C CE Compliance; viii Cleaning; 23 E Electrical Connections; 7 F FCC Compliance; viii G General View; ix Glossary; 26 Guide

Pagina 36 - GLOSSARY

DECLARATION OF CONFORMITY 08 Datalogic Automation S.r.l., Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares tha

Pagina 37

www.automation.datalogic.comDS2200Reference Manual

Pagina 38

REFERENCES CONVENTIONS This manual uses the following conventions: “User” or “Operator” refers to anyone using a DS2200. “Device” refers to the DS

Pagina 39

SAFETY PRECAUTIONS LASER SAFETY The following information is provided to comply with the rules imposed by international authorities and refers to

Pagina 40

The warning label indicating exposure to laser light and the device classification is applied onto the body of the scanner (Figure A, 8): CAUTION-C

Pagina 41 - DECLARATION OF CONFORMITY

CE COMPLIANCE Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be

Pagina 42

GENERAL VIEW DS2200 6547 321 8Figure A 12345678Barcode Image Input WindowLaser Beam Output WindowPower On LEDGood Read LEDExt Trig LEDTX Data

Comentarios a estos manuales

Sin comentarios