Datalogic DS2200 Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 10
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8


1 CHASSIS Cable shield internally connected by capacitor to chassis
9 VS Supply voltage - positive pin
2 GND Supply voltage - negative pin
6 VS_I/O Supply voltage of I/O circuit
3 REF_I/O Reference voltage of I/O circuit
4 SYS_ENC_I/O System signal
5 SYS_I/O System signal
7 LON A Lonworks line (polarity insensitive)
8 LON B Lonworks line (polarity insensitive)

  
1 TX + Transmitted data (+)
2 TX - Transmitted data (-)
3 RX + Received data (+)
6 RX - Received data (-)
4,5,7,8 NC Not connected
Female (all models)
9-pin Local Lonworks Connectors
RJ45 Modular Jack
Male (Master/Slave model)
9-pin Local Lonworks Connectors
In DS6400 Ethernet models a RJ45 Modular Jack is provided for Ethernet connection. This interface and the connector pinout are IEEE 802.3
10 BaseT and IEEE 802.3u 100 BaseTX compliant.

60
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10

Comentarios a estos manuales

Sin comentarios