Datalogic DX8200A Manual de instalación Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 97
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
INSTALLATION
2
RS485 Full-Duplex Interface
The RS485 full-duplex interface is used for non-polled communication protocols in
point-to-point connections over longer distances than those acceptable for RS232
communications or in electrically noisy environments. The overall maximum cable length
should not exceed 1200 m (3937 ft).
The following pins of the 26-pin connector are used for RS485 full-duplex interface
connection:
Pin Name Function
2 TX485 + RS485 output (+)
3 RX485 + RS485 input (+)
4 TX485 - RS485 output (-)
5 RX485 - RS485 input (-)
7 GND-ISO Main signal ground
DX8200A
7
GND_ISO
TX485+
2
RX485+
3
TX485-
4
RX485-
5
TX485+
TX485-
SGND Main Isolated
USER INTERFACE
RX485-
RX485+
1
Earth
Ground
CHASSIS
Figure 5 - RS485 Full-Duplex Interface Connections
11
Vista de pagina 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 96 97

Comentarios a estos manuales

Sin comentarios