20
GRYPHON™ BT DEFAULT CONFIGURATION
USB
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, character replacement disabled, address stamping = disabled,
address delimiter = disabled.
USB KEYBOARD: USA keyboard, inter-character and inter-code delays
disabled.
USB COM: no handshaking, delay disabled, rx timeout 5 sec., ack/nack
disabled, serial trigger lock disabled.
Default Headers and Terminators for each USB mode:
- USB-KBD: no header, terminator = ENTER
- USB-KBD-ALT-MODE: no header, terminator = CR
- USB-COM: no header, terminator = CR-LF
- USB-IBM-TABLE TOP: not applicable
- USB-IBM-HAND HELD: not applicable
RS232
Standard
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled,
rx timeout 5 sec., ack/nack disabled, serial trigger lock disabled;
DATA FORMAT: code identifier disabled, no field adjustment, code length not
transmitted, no header, terminator = CR-LF, character replacement disabled,
address stamping = disabled, address delimiter = disabled,
Nixdorf Mode A
9600 baud, parity odd, 8 data bits, 1 stop bit, handshaking hardware
(RTS/CTS), delay disabled, rx timeout 9.9 sec., ack/nack disabled, serial
trigger lock disabled;
DATA FORMAT: code identifier enabled, no field adjustment, code length not
transmitted, no header, terminator = CR, character replacement disabled,
address stamping = disabled, address delimiter = disabled,
Fujitsu
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, delay disabled,
rx timeout 2 sec., ack/nack disabled, serial trigger lock disabled;
DATA FORMAT: code identifier enabled, no field adjustment, code length not
transmitted, no header, terminator = CR, character replacement disabled,
address stamping = disabled, address delimiter = disabled,
ICL
9600 baud, parity even, 8 data bits, 1 stop bit, handshaking RTS always on,
delay disabled, rx timeout 9.9 sec., ack/nack disabled, serial trigger lock
disabled;
DATA FORMAT: code identifier enabled, no field adjustment, code length not
transmitted, no header, terminator = CR, character replacement disabled,
address stamping = disabled, address delimiter = disabled,