Code 128
Product Reference Guide
117
Code 128 — continued
Code 128 Length 1, Length 2 Programming Instructions
1. Scan the START barcode.
2. Scan either the Set Length 1 or Set Length 2 barcode.
3. Turn to
Appendix C, Alpha-Numeric Pad and scan the two digits (zero padded) representing
the length in decimal notation.
NOTE
For Code 128 barcodes, only the data
ch
aracters are included in the length
calculations.
4. Scan the END barcode.
START / END
PROGRAMMING BARCODES
DEFAULT SETTING FOR THIS FEATURE: 01
Set Length 1
Set Length 2
DEFAULT SETTING FOR THIS FEATURE: 80
Code 128 Conversion to Code 39
Enables/disables expansion of Code 128 labels to Code 39.
START / END
PROGRAMMING BARCODES
Disable
DEFAULT
Enable