Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
125
9
Field Transmission
number of fields to transmit
ÌHK8Î
Read one number in the range 1 to 7 for the number of fields to transmit. Include only fields to
be transmitted.
Field Order Transmission
Read the codes corresponding to the fields to transmit in the order in which they are to be
transmitted. A field can be transmitted more than once. See example.
field 1
Ì12Î
field 2
field 3
Ì23Î
Ì34Î
field 4
field 5
Ì45Î
Ì56Î
additional field 1
additional field 2
Ì67Î
Ì78Î
The barcode is divided into 3 defined fields plus 1 additional fixed field.
Example:
Transmit in the order: Field 2, Additional Field 1, Field 1, Field 2.
Number of Fields
to Transmit
+ 4 +
Field 2
+
Additional Field 1
+
Field 1
+
Field 2