Datalogic Memor Manual de usuario

Busca en linea o descarga Manual de usuario para Computadoras móviles de mano Datalogic Memor. Datalogic Memor User`s manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 85
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
©2008 Datalogic Mobile S.r.l.
07/08
www.mobile.datalogic.com
Datalogic Mobile S.r.l.
Via S. Vitalino, 13
40012 Lippo di Calderara di Reno
Bologna - Italy
Telephone: (+39) 051-3147011
Fax: (+39) 051-3147561
World wide Sales Network
available from: www.mobile.datalogic.com/contacts
Datalogic Memor™
User’s Manual
Vista de pagina 0
1 2 3 4 5 6 ... 84 85

Indice de contenidos

Pagina 1 - User’s Manual

©2008 Datalogic Mobile S.r.l.07/08www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1340012 Lippo di Calderara di RenoBologna - ItalyTel

Pagina 2

I D F E LUCE LASER NON FISSARE IL FASCIO APPARECCHIO LASER DI CLASSE 2 MINIMA POTENZA DI USCITA: LUNGHEZZA D'ONDA EMESSA: CONFORME A EN 60825-1

Pagina 3

ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your mob

Pagina 4

NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1 und CDRH 21 CFR 1040 Normen für die Lasersicherhe

Pagina 5 - NOR DATALOGIC EQUIPMENT

ATENCIÓN La utilización de procedimientos o regulaciones diferentes de aquellas describidas en la documentación puede causar una exposición peligros

Pagina 6

RADIO COMPLIANCE In radio systems configured with mobile computers and access points, the frequencies to be used must be allowed by the spectrum aut

Pagina 7 - REFERENCES

FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the eq

Pagina 8 - SAFETY REGULATIONS

WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bidone barrato

Pagina 9 - LASER SAFETY

 éviter les retombées négatives pour l'environnement et la santé dérivant d'une élimination incorrecte  récupérer les matériaux dans le

Pagina 10 - I D F E

CHINA ROHS POLLUTION CONTROL LOGOS Toxic or Hazardous Substances and Elements Part name Pb Hg Cd Cr6+ PBB PBDE Upper Case O O O O O O Lower Case O

Pagina 11

GENERAL VIEW G BKCA F HI DJE A) Transflective 64K Color Display B) Good Read or User Programmable LED C) Charging Status LE

Pagina 12

Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Datalogic Memor™ - User's Manual Sof

Pagina 14 - Information for the User

INTRODUCTION 1 1 INTRODUCTION 1.1 DATALOGIC MEMOR™ DESCRIPTION The Datalogic Memor™ is a pocket-sized Windows powered mobile computer. This ext

Pagina 15 - PATENTS

DATALOGIC MEMOR™ 1 1 1.3 PACKAGE CONTENTS The Datalogic Memor™ package contains: − 1 Datalogic Memor™ mobile computer − 1 AC/DC power supply − 1 E

Pagina 16 - WEEE COMPLIANCE

INTRODUCTION 1 1.4 INSERTING AN SD CARD Datalogic Memor™ provides the possibility to add an SD memory storage card. To access the SD card slot and

Pagina 17

DATALOGIC MEMOR™ 1 1 1.5 ACCESSORIES  Cradles 94A151111 Datalogic Memor™ Single Cradle 94A151116 Datalogic Memor™ Single Ethernet Cradle  Batte

Pagina 18

CONNECTIONS 2 2 CONNECTIONS 2.1 USB CONNECTION You can use any standard mini USB cable to directly connect the Datalogic Memor™ to a host computer

Pagina 19 - GENERAL VIEW

DATALOGIC MEMOR™ 1 2 2.2 RS232 CONNECTION You can use a cable to directly connect the Datalogic Memor™ to a host computer to transfer data through th

Pagina 20

CONNECTIONS 2 2.3 ETHERNET CONNECTION The Datalogic Memor™ Single Ethernet Cradle provides an Ethernet connection. Connect the Ethernet cradle (Ether

Pagina 21 - 1 INTRODUCTION

DATALOGIC MEMOR™ 1 2 2.4 WLAN CONNECTION Datalogic Memor™ Wi-Fi 802.11 b/g radio models can communicate with the host using the on-board radio freque

Pagina 22 - 1.3 PACKAGE CONTENTS

CONNECTIONS 2 NOTE Wi-Fi module is on by default, in order to avoid wasting energy, you can switch it off using the Wireless Communications applet.

Pagina 23 - 1.4 INSERTING AN SD CARD

CONTENTS DATALOGIC END USER LICENSE AGREEMENT ...v REFERENCES...

Pagina 24 - 1.5 ACCESSORIES

DATALOGIC MEMOR™ 1 2 2.5 WPAN CONNECTIONS Bluetooth® Datalogic Memor™ mobile computer models can communicate with a Bluetooth® device, such as a prin

Pagina 25 - 2 CONNECTIONS

CONNECTIONS 2 2.6 CONNECTION CABLES  RS232 Direct Connection: 94A051022 WIN-NET SERIAL CAB (HRS ST40x-18S-CV) RXDTXD310 29 4DSRDatalogic Memor™

Pagina 26 - 2.2 RS232 CONNECTION

DATALOGIC MEMOR™ 1 3 3 USE AND FUNCTIONING The use of the Datalogic Memor™ depends on the application software loaded. However there are several pa

Pagina 27 - 2.3 ETHERNET CONNECTION

USE AND FUNCTIONING 3 NOTE The mobile computer can also be awakened or turned off by the application program. 13

Pagina 28 - 2.4 WLAN CONNECTION

DATALOGIC MEMOR™ 1 3 3.1.1 Using the Stylus The stylus selects items and enters information. The stylus functions like a mouse. Double Tap: Touch t

Pagina 29

USE AND FUNCTIONING 3 3.1.2 Using the Joystick The joystick selects items and enters information. The joystick can work like the directional arrow k

Pagina 30 - 2.5 WPAN CONNECTIONS

DATALOGIC MEMOR™ 1 3 3.2 DATA CAPTURE To capture data first of all select the barcode icon on the bottom-right side of the display and tap the '

Pagina 31 - 2.6 CONNECTION CABLES

USE AND FUNCTIONING 3 3.3 DESCRIPTION OF THE KEYS The Datalogic Memor™ provides a 20-key alphanumeric keyboard + ON/OFF key + joystick. The followin

Pagina 32 - 3 USE AND FUNCTIONING

DATALOGIC MEMOR™ 1 3 Main Keys Function KEY FUNCTION It starts barcode data capture. The joystick lets you move forwards, backwards, upwards or d

Pagina 33

USE AND FUNCTIONING 3 3.3.1 Resetting the Memor™ There are several reset methods for the Memor™. A warm boot terminates an unresponsive application

Pagina 34 - 3.1.1 Using the Stylus

3.5.2 Capture... 28 3.6 Control Panel ...

Pagina 35 - 3.1.2 Using the Joystick

DATALOGIC MEMOR™ 1 3 Warm Boot Cold Boot Clean Boot REGISTRY Preserved Restored from flash (if available) Factory default Flash Disk (Backup Folde

Pagina 36 - 3.2.1 Laser Data Capture

USE AND FUNCTIONING 3 3.4 STATUS INDICATORS 3.4.1 LED Status The Datalogic Memor™ provides three different LEDs signaling the mobile computer statu

Pagina 37 - 3.3 DESCRIPTION OF THE KEYS

DATALOGIC MEMOR™ 1 3 ICONS DESCRIPTION Time and Battery Icons It displays the time. They are representative of five different icons indicatin

Pagina 38 - Special Function Icons

USE AND FUNCTIONING 23 3 3.5 DATA CAPTURE CONFIGURATION From the Taskbar, tap the "Decoding" icon to open a drop–down menu. Decoding can

Pagina 39 - 3.3.1 Resetting the Memor™

DATALOGIC MEMOR™ 1 3 Data Capture Configuration Window The screen format shows two columns where the left column indicates branches or parameters.

Pagina 40

USE AND FUNCTIONING 3 Alternatively using the stylus, you can tap once directly on the value on the right column; continue tapping until the desired v

Pagina 41 - 3.4.2 Taskbar

DATALOGIC MEMOR™ 1 3 Reader Parameters The barcode reading parameters and values are dependent upon the type of scanner module mounted in your mobile

Pagina 42

USE AND FUNCTIONING 3 Default Settings The following tables contain the default values for the major barcode setup parameters, according to the type

Pagina 43 - 3.5.1 Configure

DATALOGIC MEMOR™ 1 3 3.5.2 Capture The Data Capture applet (Capture) enables code reading. Data Capture Window Data Capture can also be enabled

Pagina 44

USE AND FUNCTIONING 3 3.6 CONTROL PANEL From the Desktop, double tap on the "My Device" icon and then double tap on the "Control Panel

Pagina 45

DATALOGIC END USER LICENSE AGREEMENT BY DOWNLOADING OR INSTALLING THE SOFTWARE, OR BY USING DATALOGIC EQUIPMENT THAT INCLUDES THIS SOFTWARE, YOU AR

Pagina 46 - Scan Parameters

DATALOGIC MEMOR™ 1 3 3.6.2 Registry The REGISTRY ADMIN applet provides management of Windows CE 5.0 registry. Select the REGISTRY ADMIN applet by do

Pagina 47 - Default Settings

USE AND FUNCTIONING 3 3.6.3 Files Admin The FILES ADMIN applet enables control of the permanence of files in the System Folder. Two functions are ava

Pagina 48 - 3.5.2 Capture

DATALOGIC MEMOR™ 1 3 Safe Setup First Mask Then select \Windows or a relevant sub-directory in the path box. Then, Safe Setup will recognize the ne

Pagina 49 - 3.6.1 Buttons

USE AND FUNCTIONING 3 3.6.4 Wireless Communications The WIRELESS COMMUNICATIONS applet provides management of the 802.11 b/g radio and of the Bluetoo

Pagina 50 - 3.6.2 Registry

DATALOGIC MEMOR™ 1 3 3.6.5 Ethernet Settings Datalogic Memor™ can be connected to an Ethernet network by inserting it into the Datalogic Memor™ Singl

Pagina 51 - 3.6.3 Files Admin

USE AND FUNCTIONING 3 3.6.6 Stylus Calibration You might need to recalibrate the touch screen (i.e. when you attempt to select one item with the styl

Pagina 52 - Safe Setup Second Mask

DATALOGIC MEMOR™ 1 3 Figure 2 Startup stylus calibration When starting the terminal, a stylus calibration screen comes up if valid calibration sett

Pagina 53

USE AND FUNCTIONING 3 3.7 WINDOWS CONNECTIONS To connect the Datalogic Memor™ to another device (i.e. Host PC) from Windows, several programs are ava

Pagina 54 - 3.6.5 Ethernet Settings

DATALOGIC MEMOR™ 1 3 ActiveSync® Remote NOTE Microsoft® ActiveSync® Remote is no longer supported in Windows CE. For backward compatibility you can

Pagina 55 - 3.6.6 Stylus Calibration

USE AND FUNCTIONING 3 3.7.2 Bluetooth® Manager Device Setup In order to enable a Bluetooth® device for communication with the Datalogic Memor™ you m

Pagina 56 - Startup stylus calibration

and/or copyrighted material of Datalogic. Customer shall not disclose, provide, or otherwise make available such trade secrets or copyrighted material

Pagina 57 - 3.7.1 Microsoft® ActiveSync®

DATALOGIC MEMOR™ 1 3 4. Tap on the “Discovery” button to enter the related window; then, tap on the “Scan” button to run the Discovery procedure:

Pagina 58 - ActiveSync® Remote

USE AND FUNCTIONING 3 6. Hide the Bluetooth® Manager Device window by tapping on the icon available on each window or close it through the “Close”

Pagina 59

DATALOGIC MEMOR™ 1 3 3.7.3 FTP Server Setup The Datalogic Memor™ Operating System includes a sample File Transfer Protocol (FTP) server. FTP is used

Pagina 60

USE AND FUNCTIONING 3 3.8 BACKUP DIRECTORY FILE MANAGEMENT All of the Windows CE 5.0 system files reside in RAM (volatile memory) except for the Bac

Pagina 61

DATALOGIC MEMOR™ 1 3 3.9 FIRMWARE UPDATE The Datalogic Memor™ is equipped with a tool that implements a firmware update service. This tool, called D

Pagina 62 - 3.7.3 FTP Server Setup

USE AND FUNCTIONING 3 Firmware Update Procedure 1. Download the update from the web site (see previous par.). It is a zip file containing the files:

Pagina 63

DATALOGIC MEMOR™ 1 3 whether to proceed with this operation. Select <YES> to format the flash disk. Select <NO> to preserve the current da

Pagina 64 - 3.9 FIRMWARE UPDATE

MAINTENANCE 4 4 MAINTENANCE NOTE Rechargeable backup batteries and battery packs are not initially charged. Therefore the initial operation to perfo

Pagina 65 - Firmware Update Procedure

DATALOGIC MEMOR™ 1 4 CAUTION Be careful when using sharp-edged tools to move the switch from the “disconnected” position to the "connected"

Pagina 66 - Figure 3

MAINTENANCE 4 4.2 CHARGING THE BATTERY PACK The battery pack autonomy varies according to factors, such as the frequency of barcode scanning, RF usa

Pagina 67 - 4 MAINTENANCE

REFERENCES CONVENTIONS This manual uses the following conventions: “User” refers to anyone using a Datalogic Memor™ mobile computer. “Mobile comp

Pagina 68

DATALOGIC MEMOR™ 1 4 4.3 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows. 1. Turn off the Datalogic Memor™. 2.

Pagina 69

MAINTENANCE 4 4. Install the new battery pack, first insert the bottom (contacts) side, then the upper (lock) side as indicated in the following figu

Pagina 70

DATALOGIC MEMOR™ 1 4 WARNING Use only a Datalogic Mobile approved power supply. Use of an alternative power supply will void the product warranty a

Pagina 71

MAINTENANCE 4 NOTE In order to guarantee an adequate operating autonomy, when replacing the battery pack the mobile computer checks the battery energ

Pagina 72

DATALOGIC MEMOR™ 1 5 5 TECHNICAL FEATURES 5.1 TECHNICAL DATA Datalogic Memor™ Common Features Electrical Features Power DC Supply 5 V ± 5% Ba

Pagina 73

TECHNICAL FEATURES 5 Mechanical Features Dimensions (LxWxH) 15.2 x 5.5 x 4.0 cm / 5.9 x 2.2 x 1.6in Weight (depending on model) 210 g / 7.40 oz (inc

Pagina 74 - 5 TECHNICAL FEATURES

DATALOGIC MEMOR™ 1 5 5.2 READING DIAGRAM Datalogic Memor™ XXX-9XX-XXX Typical Reading Diagram - Reading Zones (10° skew angle) 100 200 300 400 0 20

Pagina 75

TEST CODES 6 6 TEST CODES High Density Codes 0.25 mm (10 mils) Code 39 !17162H! 17162 2/5 Interleaved Ë"8NduÌ 0123456784

Pagina 76 - 5.2 READING DIAGRAM

DATALOGIC MEMOR™ 1 6 Medium Density Codes 0.38 mm (15 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784

Pagina 77 - (6450*TRMN(

TEST CODES 6 Low Density Codes 0.50 mm (20 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784 Code 128 ÌtestwÎ

Pagina 78 - Ë"8NduÌ

SAFETY REGULATIONS NOTE Read this manual carefully before performing any type of connection to the Datalogic Memor™ mobile computer. The user is r

Pagina 79

GLOSSARY Access Point A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped mobile

Pagina 80 - GLOSSARY

Host A computer that serves other mobile computers in a network, providing services such as network control, database access, special programs, super

Pagina 81

INDEX A Accessories; 4 ActiveSync® Remote; 38 B Backup Directory File Management; 43 Bluetooth® Manager Device Setup; 39 Buttons; 29 C Charging the B

Pagina 82

Using the Joystick; 15 Using the Stylus; 14 W WEEE Compliance; xvi Windows Connections; 37 Wireless Communications; 33 WLAN Connection; 8 WPAN Connec

Pagina 83

Datalogic Mobile S.r.l. Via S. Vitalino, 13 40012 - Lippo di Calderara Bologna - Italy 07 dichiara che declares that the déclare que le beschein

Pagina 84

User’s ManualDatalogic Memor™©2008 Datalogic Mobile S.r.l.07/08822000705 (Rev. E)www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1340

Pagina 85 - Via S. Vitalino, 13

LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies to both la

Comentarios a estos manuales

Sin comentarios