Datalogic QLM700 Manual de instrucciones Pagina 97

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 142
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 96
TYPICAL LAYOUTS
87
6
For a Master/Slave Multidata layout each reader has its own reading phase independent
from the others; each single message is sent from the master reader to the Host computer.
Figure 98 ID-NET™ M/S Multidata
NOTE
The auxiliary serial interface of the slave readers can be used in Local
Echo communication mode to control any single reader (visualize
collected data) or to configure it using the VisiSet™ utility.
The ID-NET™ termination resistor switches must be set to ON only in the first
and last CBX connection box.
Terminal
Main Serial Interface (RS232 or RS485)
Auxiliary Serial Interface (Local Echo) (RS232)
External Trigger (for One Shot or Phase Mode)
ID-NET™ (up to 32 devices, max network extension of 1000 m)
Host
1
4
3
2
Master
Slave#1
Slave#n
Power
Vista de pagina 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 141 142

Comentarios a estos manuales

Sin comentarios