MATRIX 210™ HOST MODE PROGRAMMING
30
4
PARAMETER TYPE SEL STRING DATA
Image Subsampling 1 1 <ESC> q b 0 = 1/1
1 = 1/4
2 = 1/16
3 = 1/64
Image Format 1 1 <ESC> q c 0 = BMP
1 = JPEG
2 = TIFF
3 = RAW
JPG Quality (1-100) 0 <ESC> q d Range: 0 to 100
FTP Server Address 2 <ESC> q e Length: 0 to 256
User Name 2 <ESC> q f Length: 0 to 256
Password 2 <ESC> q g Length: 0 to 256
Image Saving Path 2 <ESC> q h Length: 0 to 256
Image File Name 2 <ESC> q i Length: 0 to 256
Max Different Files To
Save
0 <ESC> q j Range: 0 to 1000000
File Type 1 1 <ESC> q k 0 = ASCII
1 = Binary
CBX ETHERNET/IP
Status 1 1 <ESC> q w 0 = Disabled
1 = Enabled
Header String 2 <ESC> q x Length: 0 to 128
Terminator String 2 <ESC> q y Length: 0 to 128
Keep Read Item 1 1 <ESC> q z 0 = Keep Always
1 = Discard After Read
CBX ETHERNET MODBUS TCP
Status 1 1 <ESC> M F 0 = Disabled
1 = Enabled
Header String 2 <ESC> M G Length: 0 to 128
Terminator String 2 <ESC> M H Length: 0 to 128
Start Register 0 <ESC> M I Range: 0 to 256
Number Of Registers 0 <ESC> M J Range: 0 to 256 (valid when Type =
Client)
Type 1 1 <ESC> M L 0 = Server
1 = Client
Server Address 2 <ESC> M K Length: 0 to 256
Number Of Registers 0 <ESC> M = Range: 0 to 256 (valid when Type =
Server)
CBX ETHERNET GET IP CLIENT
Product Name 2 <ESC> F X Length: 0 to 15
Comentarios a estos manuales