Datalogic STAR Modem Manual de usuario

Busca en linea o descarga Manual de usuario para Redes Datalogic STAR Modem. STAR Modem™ Reference Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 80
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Australia
Datalogic Scanning Pty Ltd
North Ryde, Australia
Telephone: [61] (2) 9870 3200
Fax: [61] (2) 9878 8688
France and Benelux
Datalogic Scanning Sarl
LES ULIS Cedex, France
Telephone: [33].01.64.86.71.00
Fax: [33].01.64 46.72.44
Germany
Datalogic Scanning GmbH
Darmstadt, Germany
Telephone: 49 (0) 61 51/93 58-0
Fax: 49 (0) 61 51/93 58 58
Italy
Datalogic Scanning SpA
Vimercate (MI), Italy
Telephone: [39] (0) 39/62903.1
Fax: [39] (0) 39/6859496
Japan
Datalogic Scanning KK
Shinagawa, Tokyo, Japan
Telephone: 81 (0)3 3491 6761
Fax: 81 (0)3 3491 6656
Latin America
Datalogic Scanning, Inc
Miami, Florida, USA
Telephone: (305) 591-3222
Fax: (305) 591-3007
Spain and Portugal
Datalogic Scanning Sarl
Sucursal en España
Madrid, Spain
Telephone: 34 91 746 28 60
Fax: 34 91 742 35 33
United Kingdom
Datalogic Scanning LTD
Watford, England
Telephone: 44 (0) 1923 809500
Fax: 44 (0) 1923 809 505
www.scanning.datalogic.com
Datalogic Scanning, Inc.
959 Terry Street
Eugene, OR 97402
Telephone: (541) 683-5700
Fax: (541) 345-7140
©2007 Datalogic Scanning, Inc. 820002020 (Rev. A)
10/07
STAR Modem™
Reference Manual
Vista de pagina 0
1 2 3 4 5 6 ... 79 80

Indice de contenidos

Pagina 1 - Reference Manual

AustraliaDatalogic Scanning Pty LtdNorth Ryde, AustraliaTelephone: [61] (2) 9870 3200Fax: [61] (2) 9878 8688France and BeneluxDatalogic Scanning SarlL

Pagina 2 - 19/10/2007

STARModem™ 4 2.1.2 STAR-System™ Mode In STAR-System™ mode, STARModem™ uniquely provides a wireless bi-directional communication between the Hos

Pagina 3 - CONTENTS

MOUNTING AND CONNECTIONS 5 2.2 STARModem™ INSTALLATION STARModem™ can be installed to operate in different positions by means of two different mo

Pagina 4

STARModem™ 6 Figure 5 - STARModem™ Standard Positions Using Mounting Brackets = 50 == 40 =4.5 n. 2 15322646257.5= 35 =3= 1.96 == 1.57 =0.1

Pagina 5

MOUNTING AND CONNECTIONS 7 2.2.2 Antenna WARNING Before proceeding with this operation ensure that the modem is not powered. An adjustable antenn

Pagina 6 - HOW TO USE THIS MANUAL

STARModem™ 8 2.3 SYSTEM CONNECTIONS CAUTION Connections should always be made with power off! STARModem™ has a dedicated 9-pin female cable

Pagina 7 - 1 INTRODUCTION

MOUNTING AND CONNECTIONS 9 NOTE By inserting the power supply connector into the power jack, pin 9 is automatically disconnected. 5 Vdc or 10 - 3

Pagina 8

STARModem™ 10 Figure 13 - Pen Emulation Interface Connection 2.3.3 Wedge Interface Connection CAUTION Before proceeding with this connectio

Pagina 9 - 2 MOUNTING AND CONNECTIONS

INTIAL SETUP 11 3 INITIAL SETUP For a correct STARModem™ configuration keep in mind the following guidelines: • when using the modem for the fir

Pagina 10 - 2.1.2 STAR-System™ Mode

STARModem™ 12 3.1 DEFINING THE SETUP For STARModem™ two different setups are provided to select communication either in Stand Alone mode or in S

Pagina 11 - 2.2.1 Mounting Brackets

INTIAL SETUP 13 3.1.1 Configuration Strings STARModem™ initial setup must be performed via serial interface by sending the configuration strings t

Pagina 12 - STARModem™

Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserve

Pagina 13 - 2.2.2 Antenna

STARModem™ 14 3.2 SETUP FOR STAND ALONE MODE 3.2.1 STARModem™ Receiver (Server) RESTORE DEFAULT Whenever necessary, send the following strin

Pagina 14 - 2.3 SYSTEM CONNECTIONS

INTIAL SETUP 15 Wedge Interface IBM AT or PS/2 PCs $+CP500$-CR 2 IBM XT $+CP503$-CR 2 PC Notebook $+CP505$-CR 2 IBM SURE1 $+CP506$-CR 2 IBM Terminal

Pagina 15 - 10 - 30 Vdc 200 mA

STARModem™ 16 3.2.2 STARModem™ Transmitter (Client) RESTORE DEFAULT Whenever necessary, send the following string to STARModem™ via RS232 to r

Pagina 16 - CAUTION

INTIAL SETUP 17 3.3 SETUP FOR STAR-SYSTEM™ MODE RESTORE DEFAULT Whenever necessary, send the following string to STARModem™ via RS232 to restore

Pagina 17 - 3 INITIAL SETUP

STARModem™ 18 4 CONFIGURATION Once the modem is setup, you can change the default parameters to meet your application needs by sending the desir

Pagina 18 - 3.1 DEFINING THE SETUP

CONFIGURATION 19 In this manual, the configuration parameters are divided into logical groups making it easy to find the desired function based on it

Pagina 19 - 3.1.1 Configuration Strings

20 RS232 PARAMETERS ~ BAUD RATE ~ ~ PARITY ~ ~ DATA BITS ~ ~ STOP BITS ~ ~ HANDSHAKING ~ ~ ACK/NACK PROTOCOL ~ ~ FIFO ~ ~ INTER-CHARACTER DELAY~

Pagina 20 - INTERFACE SELECTION

RS232 21 Description String BAUD RATE 150 baud CD0 300 baud CD1 600 baud CD2 1200 baud CD3 2400 baud CD4 4800 baud CD5 9600 baud CD6 19200 baud

Pagina 21

RS232 22 Description String HANDSHAKING see par. 5.2.1 Disable CE0 Hardware (RTS/CTS) CE1 Software (XON/XOFF) CE2 RTS always ON CE3 Modem (RTS/C

Pagina 22

23 WEDGE PARAMETERS ~ KEYBOARD NATIONALITY ~ ~ CAPS LOCK ~ ~ NUM LOCK ~ ~ STOP BITS ~ ~ INTER-CHARACTER DELAY~ ~ INTER-CODE DELAY ~ ~ KEYBOARD SE

Pagina 23 - SET RADIO ADDRESSES

iii CONTENTS HOW TO USE THIS MANUAL ...vi 1 INTRODUCTION ...

Pagina 24 - 4 CONFIGURATION

WEDGE 24 Description String KEYBOARD NATIONALITY Belgian FJ7 English FJ4 French FJ2 German FJ3 Italian FJ1 Spanish FJ6 Swedish FJ5 USA FJ0

Pagina 25 - CONFIGURATION

WEDGE 25 KEYBOARD SETTING ALPHANUMERIC KEYBOARD SETTING The reader can be used with terminals or PCs with various keyboard types and nationaliti

Pagina 26 - RS232 PARAMETERS

WEDGE 26 01 : Shift 02 : Alt 03 : Ctrl 04 : Backspace 05 : SPACE 28 : 7 51 : N 06 : ! 29 : 8 52 : O 07 : " 30 : 9 53 : P 08 : # 31 : : 54 :

Pagina 27 - STOP BITS

27 PEN EMULATION ~ OPERATING MODE ~ ~ MINIMUM OUTPUT PULSE ~ ~ CONVERSION TO CODE 39 AND CODE 128~ ~ OVERFLOW ~ ~ OUTPUT LEVEL ~ ~ IDLE LEVEL ~

Pagina 28 - RAME PACKING

PEN EMULATION 28 Description String OPERATING MODE Interpret mode (does not require $+ or $-) $] Transparent mode (does not require $+ or $-) $

Pagina 29 - WEDGE PARAMETERS

PEN EMULATION 29 Description String OUTPUT LEVEL see par. 5.3.4 Normal (white = logic level 0) DD0 Inverted (white = logic level 1) DD1 IDLE

Pagina 30 - INTER-CHARACTER DELAY

30 DATA FORMAT NOT FOR PEN INTERFACES ~ CODE IDENTIFIER ~ ~ CUSTOM CODE IDENTIFIER ~ ~ HEADER ~ ~ TERMINATOR ~ ~ HEADER POSITION ~ ~ CODE LENGT

Pagina 31 - KEYBOARD SETTING

DATA FORMAT 31 CODE IDENTIFIER TABLE CODE AIM STANDARD DATALOGIC STANDARD Custom 2/5 interleaved ] I y N 2/5 industrial ] X y P 2/5 norm

Pagina 32 - CONTROL CHARACTER EMULATION

DATA FORMAT 32 • AIM standard identifiers are not defined for all codes: the X identifier is assigned to the code for which the standard is not

Pagina 33 - PEN EMULATION

DATA FORMAT 33 Description String HEADER No header EA00 One character header EA01x Two character header EA02xx Three character header EA03xxx F

Pagina 34 - OVERFLOW

iv Inter-Character Delay... 22 RX Timeout ...

Pagina 35 - INTER-BLOCK DELAY

DATA FORMAT 34 Description String HEADER POSITION see par. 0 First frame field ES0 Before message field ES1 CODE LENGTH TX Code length not

Pagina 36 - DATA FORMAT

35 RADIO PARAMETERS ~ RF BAUD RATE ~ ~ TRANSMISSION MODE ~ ~ RADIO PROTOCOL TIMEOUT ~ ~ SINGLE STORE ~ ~ ACK/NACK FROM REMOTE HOST ~ ~ BEACON

Pagina 37 - CODE IDENTIFIER TABLE

RADIO PARAMETERS 36 Description String RF BAUD RATE (not for USA model) see par. 5.5.1 9600 baud MF0 19200 baud MF1 TRANSMISSION MODE (Clien

Pagina 38 - CUSTOM CODE IDENTIFIER

RADIO PARAMETERS 37 Description String ACK/NACK FROM REMOTE HOST (Client only) see par. 5.5.5 Disabled MR0 Enable ACK/DATA/NACK MR1 BEACON (

Pagina 39 - TERMINATOR

STARModem™ 38 5 REFERENCES 5.1 RADIO AND SERIAL COMMUNICATION CONTROLS STARModem™ communication (both radio and serial) can be controlled by

Pagina 40 - ADDRESS DELIMITER

REFERENCES 39 To help understand the various communication control possibilities among the different communication modes, we will analyze the communi

Pagina 41 - RADIO PARAMETERS

STARModem™ 40 • If Modem - ACK/NACK = enabled when the Local Host receives a message correctly, it answers STARModem™ with the ACK character. Onl

Pagina 42 - SINGLE STORE (Client only)

REFERENCES 41 Case 3 – STARModem™ in STAR-System™ Mode Figure 18 – STAR-System™ Mode Both STARModems™ are in STAR-System™ Mode and are therefo

Pagina 43 - BEACON (Client only)

STARModem™ 42 • If Modem 1 - Transmission Mode = 2 ways ACK/NACK from Remote Host = enabled FIFO = enabled Handshaking = any Single Store

Pagina 44 - 5 REFERENCES

REFERENCES 43 Case 4 – STARModem™ in Stand Alone Mode as Server (for an intelligent printer) Figure 19 – Stand Alone Mode with STARModem™ 2 Ser

Pagina 45

v 5.2.5 Frame Packing... 48 5.3 PEN Emulation Parameters

Pagina 46

STARModem™ 44 5.2 RS232 PARAMETERS 5.2.1 Handshaking Modem: (RTS/CTS) STARModem™ deactivates the RTS line when it cannot receive a character

Pagina 47

REFERENCES 45 Hardware handshaking: (RTS/CTS) The RTS line is activated by STARModem™ before transmitting a character. Transmission is possible only

Pagina 48 - STARGATE™

STARModem™ 46 5.2.2 ACK/NACK Protocol This parameter sets a transmission protocol which takes place between STARModem™ (Server) and Local Host i

Pagina 49

REFERENCES 47 If the modem does not receive an ACK, DATA or NACK, transmission is ended after the RX Timeout (see par. 5.2.3 ). See also Radio Protoc

Pagina 50 - 5.2.1 Handshaking

STARModem™ 48 5.2.5 Frame Packing This parameter defines the format of the frame to be transmitted between STARModem™ and the Host. The frame re

Pagina 51 - XON/XOFF handshaking

REFERENCES 49 Correct FRAME identification is managed by frame packing. Three different types of frame packing can be selected: • Frame+ [CR] (defa

Pagina 52 - 5.2.2 ACK/NACK Protocol

STARModem™ 50 Example 1 Sending the $+$![CR] command to transmit the modem software release: 1st Frame = #+++PROG_REQ+++# 2nd Frame = $![CR]

Pagina 53 - 5.2.4 FIFO

REFERENCES 51 5.3.4 Output and Idle Levels The following state diagrams describe the different output and idle level combinations for Pen emulation

Pagina 54 - 5.2.5 Frame Packing

STARModem™ 52 5.4 DATA FORMAT 5.4.1 Header/Terminator Selection The header/terminator selection is not effected by restore default command. In

Pagina 55 - [STX] LEN FRAME [CR]

REFERENCES 53 SET CUSTOM EXTENDED HEADER/TERMINATOR KEYS The extended Header/Terminator keys for Wedge Interface users can be customized by definin

Pagina 56 - 5.3.2 Overflow

vi HOW TO USE THIS MANUAL Your modem is supplied with its own Quick Reference Manual which provides connection diagrams, basic application parame

Pagina 57 - 5.3.5 Inter-Block Delay

STARModem™ 54 CUSTOM EXTENDED KEYBOARD SETTING TABLE Custom Order HEX KEY 01 - Shift 02 - Alt 03 - Ctrl 04 - Backspace 05 83 06 84

Pagina 58 - 5.4 DATA FORMAT

REFERENCES 55 Header Position This parameter defines the header position within the frame to be transmitted from STARModem™ to the Host. The header

Pagina 59

STARModem™ 56 If STARModem™ as Client, is transmitting to more than one destination device in 1 way mode, it is necessary to set the Host applicat

Pagina 60

REFERENCES 57 NOTE If communicating with only one RF device in 2 way mode, Address Stamping is not required, since the data/answer generated by the

Pagina 61 - 5.4.2 Address Stamping

STARModem™ 58 5.5.3 Radio Protocol Timeout (Client only) This parameter sets the valid time to wait before radio transmission between STARModem™

Pagina 62 - Modem™

REFERENCES 59 One way mode: Host sends a message to STARModem™ which passes it to the destination device via radio. In case of good transmission, th

Pagina 63 - 5.5 RADIO PARAMETERS

STARModem™ 60 5.5.6 Beacon (Client only) This parameter is available only when STARModem™ is used in STAR-System™ applications and is connected

Pagina 64

DEFAULT CONFIGURATION 61 6 DEFAULT CONFIGURATION Configuration Parameter Default Setting RS232 Communication Baud Rate 9600 Parity, Data Bits, S

Pagina 65 - 2 Way Transmission Mode

STARModem™ 62 Configuration Parameter Default Setting Radio Parameters European Models USA Models RF Baud Rate 19200 baud 36800 baud Transmissi

Pagina 66 - 5.5.6 Beacon (Client only)

TECHNICAL FEATURES 63 7 TECHNICAL FEATURES Electrical Features 5 Volt Models 10-30 Volt Models Supply voltage 5 Vdc ± 5% 10 to 30 Vdc Power co

Pagina 67 - 6 DEFAULT CONFIGURATION

INTRODUCTION 1 1 INTRODUCTION STARModem™ is a radio modem developed to provide wireless 433 MHz RF (European models) / 910 MHz (USA model) commun

Pagina 68

STARModem™ 64 A TYPICAL SYSTEM LAYOUTS The following examples give a graphical representation of STARModem™ application in 5 typical layouts an

Pagina 69 - 7 TECHNICAL FEATURES

TYPICAL SYSTEM LAYOUTS 65 A.1 STAND ALONE MODE - STARModem™ SERVER STARModem™ is connected to an Host PC via serial interface and receives data f

Pagina 70 - A TYPICAL SYSTEM LAYOUTS

STARModem™ 66 DRAGON 2 - Setup for Stand Alone Mode - DRAGON™ M Radio Address = 1236 - STARModem™ Address = 0010 - Transmission Mode = Two ways

Pagina 71

TYPICAL SYSTEM LAYOUTS 67 For connection with the DL8700 terminal, the STARModem™ 5 Volt model is powered directly by the terminal through pin 9 of

Pagina 72

STARModem™ 68 Each system device may be configured as follows: STARModem™ - Setup for STAR-System™ mode - STARModem™ Radio Address = 0502 - Fi

Pagina 73 - TYPICAL SYSTEM LAYOUTS

TYPICAL SYSTEM LAYOUTS 69 HOST 1 - Run the desired application or a terminal emulation program. - Adjust the Host communication parameters and hand

Pagina 74 - Modem 2

STARModem™ 70 Each system device must be configured as follows: STARModem™ - Setup for STAR-System™ mode - STARModem™ Radio Address = 0682 - F

Pagina 75 - Modem™ Client

HEX AND NUMERIC TABLE 71 B HEX AND NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE char hex char hex char hex NUL 00 * 2A U 55 SOH 01 +

Pagina 76

72 GLOSSARY 1 way transmission a radio transmission in which STARModem™ transmits data without requiring an acknowledgement answer from the remo

Pagina 77 - B HEX AND NUMERIC TABLE

73 STAR-System™ a Datalogic radio communication system that uses a Narrow Band RF radio and Datalogic proprietary CSMA/CA protocol to automatically

Pagina 78 - GLOSSARY

STARModem™ 2 Each LED signals a different modem functioning as reported in the table below: LED DESCRIPTION Power On Green constant STARModem™

Pagina 79

AustraliaDatalogic Scanning Pty LtdNorth Ryde, AustraliaTelephone: [61] (2) 9870 3200Fax: [61] (2) 9878 8688France and BeneluxDatalogic Scanning SarlL

Pagina 80

MOUNTING AND CONNECTIONS 3 2 MOUNTING AND CONNECTIONS 2.1 BASIC SYSTEM LAYOUTS There are two basic system layouts that can be employed: stand al

Comentarios a estos manuales

Sin comentarios