INSTALLATION
25
2
Reading Performance Window
This window displays the following data:
P a c k o u t = 1 2 4 6 7
G o o d r e a d = 1 2 4 6 7
N o r e a d = 0
M u l t i p l e r e a d = 0
Number of processed parcels
Number of Good Reads
Number of No Reads
Number of Multiple Reads
Reading Mask Window
This window indicates the node that performed a reading of the codes enabled on the
master.
R e a d * *
m a s k A B C D E F G H
The following indicators are used:
*
The node read a barcode enabled on the master.
<space>
The node read no barcode.
I/O Status Window
This window provides data concerning the digital input/output status.
E N C = 0 P S = 0 P S A U X = 0
I N 1 = 1 I N 2 = 0 I N 3 = 0
O U T 1 = 0 O U T 2 = 0 O U T 3 = 0
O U T 4 = 0 O U T 5 = 0 O U T 6 = 0
0 = Low Level Signal
1 = High Level Signal
Conveyor Speed Window
This window provides data concerning the conveyor speed.
C o n v e y o r s p e e d
x x ( m m / s e c )
x x ( f t / m i n )