Datalogic SC6000-1200 Manual de instrucciones Pagina 58

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 77
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 57
SC6000
48
3
Parameter
Default Setting
Built-in Ethernet Port
LineParameters
Status Enabled (checked)
Eth_speed Auto
DHCP Disabled (unchecked)
IP_address 172.16.11.221
IP_netmask 255.255.0.0
IP_gateway 127.0.0.1
IP_dns1 127.0.0.1
IP_dns2 127.0.0.1
Services All disabled (unchecked)
Modem Serial Port
Data Tx Disabled (unchecked)
Parameters
Baud Rate 38400
Modem Enabled Disabled (unchecked)
Digital I/O Settings
Digital Input Lines Settings
Debouncing for Input 1, 2 and 3 5 ms
Debouncing for Encoder 500 µs
Debouncing for PS and PSAUX 5 ms
PS Active Level (Overridden by Op. Mode) Active Closed
PSAUX Active Level (Overridden by Op. Mode) Active Closed
Input 1 Active Level (Overridden by Op. Mode) Active Closed
Input 2 Active Level (Overridden by Op. Mode) Active Closed
Input 3 Active Level (Overridden by Op. Mode) Active Closed
Digital Output Lines Setting
Output 1
Use Local
Line State Normally Open
Activation Event Complete Read
Alternative Activation Event Multiple Read
Deactivation Event Timeout
Alternative Deactivation Event None
Activate on Error Disabled (unchecked)
Deactivate when Errors Recovered Disabled (unchecked)
Deactivation Timeout (ms) 50
Output 2
Use Local
Line State Normally Open
Activation Event No Read
Alternative Activation Event Partial Read
Deactivation Event Timeout
Alternative Deactivation Event None
Vista de pagina 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 76 77