Datalogic QLM500 Manual de instalación Pagina 99

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 119
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 98
READING FEATURES
87
7
7.1.3 Advanced Code Reconstruction Reading Conditions
The following tables describe the minimum code height requirements (in mm) for standard
ACR-Lite applications depending on the code symbology and the given reading conditions.
ANSI Grade B minimum
800 scans/sec
three code symbologies enabled simultaneously
uniform background
2/5 Interleaved
Minimum Code Height for ACR-Lite Reading (mm)
45° max
30° max
Conveyor Speed (m/s)
0.5
.75
1
0.5
.75
1
Code Resolution
(mm)
0.20
17
20
23
12
14
16
0.35
28
30
32
18
20
22
0.50
34
36
38
23
25
27
Ratio 2.5:1
Table 1
Code 39
Minimum Code Height for ACR-Lite Reading (mm)
45° max
30° max
Conveyor Speed (m/s)
0.5
.75
1
0.5
.75
1
Code Resolution
(mm)
0.20
16
19
22
12
14
16
0.35
26
28
30
17
19
21
0.50
31
33
35
21
23
25
Ratio 2.5:1; Interdigit = Module Size
Table 2
Code 128 GS1-128
Minimum Code Height for ACR-Lite Reading (mm)
45° max
30° max
Conveyor Speed (m/s)
0.5
.75
1
0.5
.75
1
Code Resolution
(mm)
0.20
12
15
18
9
11
14
0.35
22
25
28
13
16
19
0.50
25
27
30
17
20
23
Table 3
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
Vista de pagina 98
1 2 ... 94 95 96 97 98 99 100 101 102 103 104 ... 118 119

Comentarios a estos manuales

Sin comentarios