25-PIN CABLE ELECTRICAL CONNECTIONS
59
5
5.2.3 RS485 Half-Duplex Interface
NOTE
This interface is provided for backward compatibility. We recommend using
the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts.
The RS485 half-duplex (3 wires + shield) interface is used for polled communication
protocols.
It can be used for Multidrop connections with a Datalogic Multiplexer, (see par. 6.5) exploiting
a proprietar
y protocol based on polled mode called MUX32 protocol, where a master device
polls slave devices to collect data.
The connector pinout follows:
25-pin
Name Function
2 RTX+ RS485 Receive/Transmit Data +
4 RTX- RS485 Receive/Transmit Data -
7 GND Ground
RTX+
2
RTX-
4
RTX485 +
RTX485 -
7
GND
MULTIPLEXER
RS485REF
DS2400N
1
Chassis
Figure 65 - RS485 Half-duplex Connections
This interface is forced by software when the protocol selected is MUX32 protocol.
In a Multiplexer layout, the Multidrop address must also be set via serial channel by the
Genius™ utility or by the Host Programming Mode.
Figure 66 shows a multidrop configuration with DS2400N scanners connected to a
Multiplexer.
CAUTION
This is an example of multidrop wiring. Consult the multiplexer manual for
complete wiring instructions.