ALTERNATIVE LAYOUTS
111
A
In general, for all point-to-point layouts, DX8200A Vac models can substitute the Vdc model
and therefore eliminate the PWR power supply. This requires that the CBX100/CBX500 must
have the correct Power Source jumper setting to accept scanner power for the P.S.
* CBX100/CBX500 jumper set to accept scanner power
Figure 99 – Point-to-Point for Standard AC Models
Fieldbus Models
In this case no External Trigger/PS is used and the CBX100/CBX500 only passes power to
the reader. The DX8200A (Ethernet, DeviceNet or Profibus model) is connected to a fieldbus
remote Host. It can be activated by a signal generated by the remote Host or always be
active if working in Automatic operating mode.
Figure 100 – Point-to-Point for Fieldbus DC Models
Remote Host
CBX
CAB-F0x
PWR-120
Fieldbus
Network
I/O, AUX
DX8200A
Standard
Vac model
1
2
3
Main Serial Interface
(RS232 or RS485 Full-Duplex)
I/O and/or Auxiliary Serial Interface
(Data Tx to Terminal Local Echo) (RS232)
Input 1 (External Trigger/PS input)
Host
CBX*
CAB-F0x
110 - 230 Vac
DX8200A
Fieldbus
model