Enter/Exit Programming Mode
Product Reference Guide
171
Plessey Set Length 2
This feature specifies one of the bar code lengths for Plessey Length Con-
trol. Length 2 is the maximum label length if in Variable Length Mode, or
the second fixed length if in Fixed Length Mode. Length includes the bar
code’s check, data, and full-ASCII shif
t ch
aracters. The length does not
include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to
ignore this length (only one fixed length).
Table 25 provides examples for setting Length 2. See page 284 for detailed
instructions on setting this feature.
Table 25. Plessey Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT PLESSEY LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CPLL2
Select Plessey Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters