This feature specifies one of the bar code lengths for Datalogic 2 of 5 Length Control.
Length 2 is the maximum label length if in
Variable Length Mode, or the second fixed length
if in
Fixed Length Mode. The length includes the bar code’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 00 specifies to ignore this length
(only one fixed length). See
Set Length 2 on page 269 for more detailed programming
instructions.