Label Gone Timeout
Product Reference Guide 19
ENTER/EXIT PROGRAMMING MODE
Label Gone Timeout
This feature sets the time after the last label segment is seen before the reader prepares for a new
label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 sec-
onds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a
trigger pull for each label that is read. See
Label Gone Timeout on page 244 for more
detailed programming instructions.
$CSNLG
Select Label Gone Timeout Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
016 = Timeout of 160 ms