Datalogic QuickScan Lite QW2100 Especificaciones Pagina 211

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 324
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 210
Standard 2 of 5
Product Reference Guide 201
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 — cont.
Standard 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control. Length
2 is the maximum label length if in
Variable Length Mode, or the second fixed length if in
Fixed Length Mode. Length includes the bar code’s check and data characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length
(only one fixed length). See
Set Length 2 on page 269 for more detailed programming
instructions.
$CS2L2
Select Standard 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters
Vista de pagina 210
1 2 ... 206 207 208 209 210 211 212 213 214 215 216 ... 323 324

Comentarios a estos manuales

Sin comentarios