TECHNICAL FEATURES
5
5 TECHNICAL FEATURES
5.1 TECHNICAL DATA
Datalogic Memor™ Common Features
Electrical Features
Power
DC Supply 5 V ± 5%
(nominal)
Alternatively 1 cell Li-Pol or Li-Ion 2000
Internal Backup Battery Rechargeable Ni-MH 30 mAh (2 x 15 mAh cells)
Communication Features
Windows CE COM
Port
Windows Mobile
COM Port
Bluetooth® Interface
COM5 COM5
Serial Interface RS232
USB 1.1
COM1
COM6
COM1
COM6
Wireless Features
WLAN IEEE 802.11b/g DSSS
WPAN
Bluetooth
® IEEE 802.15, Class 2, Version 2.0
WWAN GSM Quad-band (850, 900, 1800, 1900 MHz)
Radio with accessible SIM card interface
Environmental Features
Working Temperature* 0° to +50 °C / 32 °F to +122 °F
Storage Temperature -20° to +70 °C / -4° to +158 °F
Humidity** 10 to 80% non condensing
for temperatures < 38 °C
Protection IP 54
ESD Protection 4 KV contact discharge, 8 KV air discharge
Drop Resistance*** 1.2 m / 3 ft 9 in
* Battery must be charged at a temperature ranging from 0° to +40 °C.
For the GSM models the maximum recommended temperature is +35°C. At higher values the
charging may slow down
Close to the limits of the working temperature, some display and/or battery performance
degradation may occur.
When the battery is exhausted, the GSM turns off and it is not working until the battery is
charged or changed.
** Multiple rapid humidity and/or temperature variations may cause condensing.
*** Multiple drops can permanently damage the device.