Vista de pagina 11
OM4000
4
2
2.3 ELECTRICAL CONNECTION
The OM4000 has a four-wire cable that extends from the compression connector and
allows connection to the C-Box of the scanner.
To facilitate quick connections for maintenance or replacement, the accessory
connection cable with 9-pin female connector and corresponding 9-pin male
connector can be wired between the C-Box and the OM4000.
The following signals must be connected:
Wire Color Signal Function
Red VS Power Supply +
Black GND Power Supply -
Yellow EXT TRIG+ External Trigger input +
Brown EXT TRIG- External Trigger input -
Scanner
with OM4000
C-Box
System cables
Scanner
connected to
C-Box
OM4000 cable wired
directly to C-Box for
power and input
signals
Figure 6 - Electrical connection to C-Box