OM4000
4
4 TECHNICAL FEATURES
ELECTRICAL CHARACTERISTICS
Operating voltage
Input current max
Power consumption max
Raster width
Oscillation frequency
10 to 30 Vdc
250 mA @ 10 Vdc
3 W @ 30 Vdc
user adjustable from 0° to 40°
(for further details see paragraph 2.5)
user adjustable from 0.5 Hz to 20 Hz
(for further details see paragraph 2.5)
READING FEATURES
See paragraph 2.4, Appendix A, and the scanner Installation manual
ENVIRONMENTAL FEATURES
Operating temperature
Storage temperature
Max. relative humidity
Vibration Resistance
Shock resistance
Protection class
0° to +40 °C (+32° to +104 °F)
-20° to +70 °C (-4° to +158 °F)
90% non condensing
IEC 68-2-6 Test FC
0.5 G @ 9 to 150 Hz; x, y, z axis for 2
hours
IEC 68-2-27 Test EA
30 G; 11 ms; 3 shocks x, y, z axis
IP64 (when correctly mounted to the
scanner)
PHYSICAL FEATURES
Mechanical dimensions
Weight
74 x 101 x 58 mm (2.9 x 4.0 x 2.3 in.)
approximately 650 g (23 oz)
Note: the features indicated are to be considered typical at an ambient temperature of 25 °C
(77 °F), if not specified differently.