Datalogic DS4300 Manual de instalación Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 23
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
READING DIAGRAM
A
A READING DIAGRAMS
A.1 EXAMPLE READING DIAGRAM
The following reading diagram is given as an example of performance that can be
obtained in optimal conditions using a high grade printed barcode. It demonstrates
the reading field in the case where the extreme ends of oscillation are set for
±
20° or
±
12°.
You should verify your application specific reading conditions taking into account the
factors listed in par. 2.4 and that the maximum reading distance is less at the
extreme ends of the sweep.
DS4600-X10X
0 100 200
300 400 500
200
150
100
50
0
50
100
150
200
mm
700 mm600
-12°
-20°
+20°
+12°
±12°
±20°
650
690
TOP VIEW
SIDE VIEW
Reading
Zone
TOP
VIEW
610
674
650
690
Reading
Zone
Conditions:
Test Code: = 2/5 Interleaved; 0.50 mm
Reading Mode = Linear
Code Resolution = Standard
Scanning Speed = Speed_3 (800 scans/s)
Code Reading Cond. = Standard