2.5 ADJUSTMENT
The OM4000 can be configured to operate in different modes by setting hardware
switches located inside the oscillating mirror body. See the figure below. To access
these switches you must remove the four cover screws shown in the figure below.
Figure 9 - Opening the OM4000 body for configuration
The following operating modes can be configured:
•
Oscillating - mirror always oscillating (see par. 2.5.1).
•
Triggered - mirror stopped after reading phase off (see par. 2.5.2).
•
Fixed - mirror set to fixed angle (see par. 2.5.3).
The following table describes the allowable switch settings for OM4000 configuration.
Operating Modes
Switches Oscillating Triggered Fixed
Mode 1 0 indifferent
Min Position 1-D 1-D 0
Max Position 3-F 3-F 1-F
Frequency 1-F 1-F indifferent
Table 1 - Allowable switch settings
Combinations other than those specified in the table are erroneous and will cause the
red ERROR LED to turn on.