Bluetooth Features
5-10 PowerScan® 7000BT SRI
BT Beep Duration
Use this feature to set the duration of configurable BT-specific beeps.
Settings are in increments of 10 milliseconds.
START/END
MODE BAR CODE
Sets the BT Beep Duration using a value from 001 to
255. Settings are in 10 millisecond increments.
To configure this feature, scan the “START/END” bar
code above to place the unit in Programming Mode,
then the “Set BT Beep Duration,” followed by the
three characters (zero padded) from the Alphanu-
meric table in
Appendix C, Alpha-Numeric Pad
representing your setting. Exit programming mode by
scanning the “START/END” bar code above.
SETTINGS EXAMPLES:
007 = 70 milliseconds
042 = 420 milliseconds
158 = 1.58 seconds 255 = 2.55 seconds
DEFAULT SETTING FOR THIS FEATURE:
006 (80 milliseconds)
Set BT
Beep Duration