Datalogic POWERSCAN PBT7100 guide Manual de instrucciones Pagina 173

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 272
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 172
Interleaved 2 of 5
Product Reference Guide 6-57
Interleaved 2 of 5 — continued
Interleaved 2 of 5 Length 1, Length 2 Pro-
gramming Instructions
1. Scan the START/END bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
3. Turn to
Appendix C, Alpha-Numeric Pad and scan the three digits
(zero padded) representing the length in decimal notation
.
4. Scan the START/END bar code.
NOTE
For Interleaved 2 of 5 bar codes, lengths must
be an even number. Additionally, all check and
data characters are included in the length calcu-
lations.
START/END
SETTING BAR CODE
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 006
Set Length 2
DEFAULT SETTING FOR THIS FEATURE:
050 decimal
Vista de pagina 172
1 2 ... 168 169 170 171 172 173 174 175 176 177 178 ... 271 272

Comentarios a estos manuales

Sin comentarios