GWY-01-DNT-01 MANUAL – REV. 02 CHAPTER 4:
COMMAND MAPPING
PAGE 34 OF 67
COMMAND ID COMMAND NAME DESCRIPTION
0x13
Get Node Status
List
Retrieves the operational status of
the Gateway Subnet Nodes
0x14
Get Notification
Mask
Retrieves the user-defined 16-bit
“Notification Mask” that
determines for which events the
Gateway notifies the host PC
0x15
Get Last Gateway
Error
Retrieves information from the
Gateway regarding the last or
most recent error that was
experienced
0x16
Get Gateway Time
Retrieves the current date and
time as set internally on the
Gateway
0x1C
Get Subnet Baud
Rate
Retrieves the baud rate of the
Subnet network
0x21
Set Gateway Name
Writes to flash memory, a user-
defined “friendly” name for the
Gateway
0x24
Set Notification
Mask
Used to customize or modify the
Gateway’s 16-bit Notification
Mask
0x26
Set Gateway Time
Used to set the Gateway’s
internal clock and calendar
0x2C
Set Subnet Baud
Rate
Used to modify and store changes
to the Subnet network baud rate
RFID Controller Commands
0x30
Get Controller
Name
Retrieves the controller’s user-
defined name
0x33
Get Controller
Configuration
Retrieves the controller’s
configuration settings
0x38
Get Controller Info
Retrieves hardware, firmware and
serial number information from
the controller
0x40
Set Controller
Name
Used to set (create or modify) the
user-defined name for the
controller
0x43
Set Controller
Configuration
Used to set (configure or modify)
the controller’s configuration
parameters and settings
Comentarios a estos manuales