Datalogic GWY-01-PBS-01 Especificaciones Pagina 45

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 67
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 44
GWY-01-DNT-01 MANUAL – REV. 02 CHAPTER 4:
COMMAND MAPPING
PAGE 45 OF 67
4.8.2 Notification Mask Example
In the following example, an RFID controller is attached to the Gateway’s Subnet
network. After power is applied to the controller, the Gateway immediately attempts
to determine its Node ID (Node 04 in this example). After recognizing a stored Node
ID configuration, the Gateway allows the device onto the Subnet network.
Now if bit 01 in the Notification Mask was enabled (set to one = ON), Notification
Event 01 would be triggered and the Gateway would immediately write Notification
Message 01 to Node Output Page 36 (the Node Output Page number for Node ID
04). The Notification Message would indicate that a new controller was recognized at
Node 04 and is functioning properly (i.e. the controller is healthy).
If, on the other hand, the recently connected controller does not power-up, or fails to
initialize properly, and bit 02 in the Notification Mask is enabled, Notification Event
02 will be triggered, in which case the Gateway will write Notification Message 02 to
Node Output Page 36. This message informs the host that the controller at Node 04
is experiencing a problem.
4.8.3 Notification Message Packet Structure
DESCRIPTION MSB LSB
Overall Length of Notification
Message (in words)
0x00 0x06
0xFE in MSB = Notification Message
Flag
Notification Event in LSB
0xFE <Notification Event>
Instance Counter in MSB (a
Notification Message is considered a
response; therefore the Instance
Counter will be incremented by one)
Node ID in LSB (04 for the above
example)
<IC> 0x04
Month and Day Timestamp
<Month> <Day>
Hour and Minute Timestamp
<Hour> <Minute>
Seconds Timestamp in MSB
0x00 in LSB
<Second> 0x00
Table 4-7: Notification Message - Packet Structure