Datalogic Laser Barcode Reader DS4600A-2XX5 Manual de instalación Pagina 35

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 105
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 34
INSTALLATION
2
Auxiliary Interface
The auxiliary serial interface is equipped with RS232 full-duplex interface connections. The
interface type is exclusive and is selectable through the Genius™ configuration program. The
overall maximum cable length should not exceed 15 m (50 ft).
The following pins of the 25-pin and 26-pin connector are used for RS232 full-duplex
interface connection:
Pin Name Function
20 RXAUX Receive data
21 TXAUX Transmit data
23 SGND AUX Auxiliary signal ground
DS6300
USER INTERFACE
23
SGNDAUX
GND
TXD
RXAUX
20
RXD
TXAUX
21
1
Earth
Ground
CHASSIS
Figure 23 - RS232 Auxiliary Interface Connections