TROUBLESHOOTING
105
11
11 TROUBLESHOOTING
NOTE
Before contacting your local Datalogic office or Datalogic Partner or ARC, it
is suggested to save the device configuration to a *.ddc file by means of the
Genius™ software configuration program and check the device exact model
and serial number.
TROUBLESHOOTING GUIDE
Problem Suggestion
Power On:
the “Power On” LED is not lit.
Is power connected?
If using an external power supply (like PWR-
120), is it connected to the AC source?
If using rail power, does rail have power?
If using CBX100/CBX500, does it have power
(check switch and LED)?
Check if you are referring to the
26-pin connector or to the CBX100/CBX500
spring clamp connectors.
Measure voltage at pin 13 and 25 (for 26-pin
connector) or at spring clamp Vdc and GND
(for CBX100/CBX500).
On Line Mode:
the Master’s “Phase On” LED is not lit
(when external trigger/PS activates).
Check carefully if you are referring to the
26-pin connector or to the CBX100/CBX500
spring clamp connectors.
Is sensor connected to EXT TRIG/PS input?
Is power supplied to photo sensor?
Is power supplied to one out of the two EXT
TRIG/PS (NPN output)?
Is one out of the two EXT TRIG/PS grounded
(PNP output)?
Are the photo sensor LEDs (if any) working
correctly?
Is the sensor/reflector system aligned (if
present)?
On Line Mode:
the Master’s “Phase On” LED is
correctly lit but nothing happens (no
reading results).
Is the software configuration consistent with
the application condition (operating mode,
etc.)?
In the Genius™ software configuration
program select the OPERATING MODES
folder and check for related parameters.
Serial On Line Mode:
the reader is not triggered (no reading
results).
In the Genius™ program select the
OPERATING MODE folder and check if
serial on line is enabled as “On Line options”
parameter value.
Are the Start-Stop string correctly assigned?
Is the serial trigger source correctly
connected and configured)