INSTALLATION
15
2
X-axis Reference Point Stops
The 2 washers and 2 spacers can be mounted to the Reading Station Frame using Bosch T-
bolts and nuts to create 2 stops which can be used to facilitate DX8200A mounting and
positioning.
During initial mounting, affix the stops in approximation to the mounting position. The
weight of the DX8200A can rest against this reference while the mounting bolts are being
set. This avoids having to hold and maneuver the scanner (especially for vertical side
mounted positions) while simultaneously affixing it to the frame.
Once the scanner is correctly positioned for PackTrack, fix the stops against the scanner.
The stops remain fixed to the station frame so that the scanner can be replaced without
having to recalibrate the PackTrack coordinates. Referring to the figure above, the stop
provides a reference point for the X-axis while the scanner should be centered on the
frame to have a fixed reference for the Y-axis.
Create the stop by
using the washer,
spacer, t-bolt and nut.
Z
Y
X