Datalogic DS2100N Manual de usuario Pagina 26

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 34
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
Setup Procedure Using Programming Barcodes
22
2.2 FOR MATRIX 410 OR MATRIX 210 FAMILY READERS
For Matrix 410 or Matrix 210 readers
5
having software 6.10 or later, connected to either a
QL500 or a BM2x0 module (inside a CBX connection box), you can setup the CBX Ethernet
communication with programming barcodes.
Ì$CBETHD$-}Î
CBX Ethernet TCP/IP enabled
DHCP enabled
Using the X-PRESS™ interface setup functions described in the Quick Reference Guide,
correctly position the reader and read one of these barcodes with the Learn function
.
The reader can now communicate using CBX Ethernet TCP/IP.
For reader configuration through VisiSet™ using Ethernet TCP/IP, follow one of the
procedures in par. 2.3.
Ì$CBETHN$-\Î
CBX Ethernet TCP/IP enabled
DHCP disabled
(uses static IP Address parameters) *
The Factory Default static IP address parameter settings for CBX Ethernet TCP/IP for all
Matrix 410 or Matrix 210 readers are:
IP Address = 172.24.24.1
Subnet Mask = 255.255.0.0
Gateway Address = 172.24.255.254
5
Except Matrix 210™ UHD models.
Vista de pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 32 33 34

Comentarios a estos manuales

Sin comentarios