Setup Procedure Using Programming Barcodes
23
For Matrix 410 or Matrix 210 Ethernet readers
6
having software 6.10 or later, you can Enable
the DHCP Addressing by reading the following programming barcode.
Ì$CBETHE$-ÈÎ
Embedded Ethernet TCP/IP enabled
DHCP enabled
Using the X-PRESS™ interface setup functions described in the Quick Reference Guide,
correctly position the reader and read the barcode with the Learn function
.
The reader can now communicate using the Embedded Ethernet TCP/IP with DHCP
addressing.
For reader configuration through VisiSet™ using Embedded Ethernet TCP/IP with DHCP,
follow the procedures in par. 2.3.1.
The Factory Default sta
tic IP address parameter settings for Embedded Ethernet for all
Matrix 410 or Matrix 210 readers are:
IP Address = 172.24.24.1
Subnet Mask = 255.255.0.0
Gateway Address = 172.24.255.254
NOTE
For Matrix 410™ or Matrix 210™ Ethernet models, Ethernet TCP/IP is
enabled with the above static IP address parameter settings by default.
Therefore, to disable the DHCP for the Embedded Ethernet it is necessary
to Restore the Factory Default (see par. 1.3).
6
Except Matrix 210™ UHD models.