Setup Procedure Using Programming Barcodes
24
2.3 IP ADDRESS ALIGNMENT PROCEDURES FOR CONFIGURATION
In order to connect a Matrix reader to VisiSet™ using Embedded Ethernet TCP/IP or CBX
Ethernet TCP/IP, the Ethernet IP Addressing parameters must be aligned between VisiSet™
and the reader.
In order to find the reader using the VisiSet™ "Look For Devices On Network" tool, the
reader and VisiSet™ must be on the same network (not through a sub-network or
router).
The following procedures can be used:
2.3.1 DHCP Enabled
1. Read the CBX Ethernet TCP/IP enabled DHCP enabled barcode or Embedded
Ethernet TCP/IP enabled DHCP enabled barcode using the X-PRESS™ Autolearn
function (as described in chapter 1).
2. In VisiSet select the Ethernet Communication Channel in the Options>Communication
window. Then press the Look For Devices On Network button. The Matrix reader will
appear with its assigned IP Address in the list. If more than one device is found, verify
the correct device by its MAC Address written on the product label.
3. Input the IP address from the list in the IP Address field of the Device Ethernet
Channel Address section of the VisiSet™ Options>Communication window (or
double-click on the device in the list). The IP port number is 51235. Then click Save.
4. Perform a Connect (to device) from VisiSet™.
NOTE
Devices working in DHCP may be assigned different IP addresses at each
powerup, therefore steps 2 - 4 of the above procedure may need to be
repeated at successive connections between VisiSet™ and the reader.