PROGRAMMING STRINGS
13
3
3.3 HOW TO GET SINGLE PARAMETER FROM THE READER
NOTE
To guarantee the complete compatibility with future software releases, It is
strongly suggested to use the shortcuts programming strings.
Using Complete Parameter Path
The 'Get Parameter' programming string must have the following format:
GP<space>PATH<CR><LF>
Where:
GP:
'Get Parameter' command.
PATH:
Complete Parameter Path.
After entering this command, the device responds with the proper reply message and then
waits for one or more programming strings.
If the programming is correct, the device updates the configuration and confirms with the
following message:
Y<space>VALUE<CR><LF>
Where:
VALUE:
Parameter Value.
If programming contents are wrong (i.e. a typing error in the file) or due to a transmission
error, the device replies with the following message:
N<space>ERRCODE<CR><LF>
Where:
ERRCODE:
Error Code (signed DEC value)
For information on Error Codes see the "Error Codes Table" in the Appendix.