SC6000 HOST MODE PROGRAMMING
50
4
PARAMETER COMPLETE PATH SHC PT VALUE
Protocol /Comms/Ethernet
/Services/UserSocket#N
/Protocol
137 1 0 = TCP
1 = UDP
Port Number /Comms/Ethernet
/Services/UserSocket#N
/Port
138 0 Range: 0 to 65535
DEVICENET
Data Tx /Comms/DeviceNet
/DeviceNet
381 1 0 = Disable
1 = Enable
DEVICENET / INTERNAL PARAMETERS
Parameters Updating /Comms/DeviceNet
/System/UpdatePar
- 1 0 = Disable
1 = Enable
DEVICENET / DATA PORT PROTOCOL
Serial Protocol /Comms/DeviceNet
/SerialData/Protocol
- 1 0 = Generic/Std
1 = Generic/Rev
4 = Header/Std
5 = Header/Rev
Termination Char
Enable
/Comms/DeviceNet
/SerialData
/InStrSuffixEnable
- 1 0 = Disable
1 = Enable
Termination Char
Value
/Comms/DeviceNet
/SerialData
/InStrSuffixValue
- 0 Range: 0 to 31
Buffer Flush Enable /Comms/DeviceNet
/SerialData
/BufFlushEnable
- 1 0 = Disable
1 = Enable
Buffer Flush Delay
(milliseconds)
/Comms/DeviceNet
/SerialData
/BufFlushDelay
- 0 Range: 8 to 9999
DEVICENET / BUS COMMUNICATION
Data Rate /Comms/DeviceNet
/BusData/BusRate
- 1 0 = 125K
1 = 250K
2 = 500k
Node Address
(MAC ID)
/Comms/DeviceNet
/BusData/NodeAddr
- 0 Range: 0 to 63
Protocol /Comms/DeviceNet
/BusData/Protocol
- 1 0 = Polled
1 = Bit Strobe
2 = Change of State
Master Input Area
Size
/Comms/DeviceNet
/BusData/TxMsgSize
- 0 Range: 0 to 254
Master Output Area
Size
/Comms/DeviceNet
/BusData/RxMsgSize
- 0 Range: 0 to 254
PROFIBUS
Data Tx /Comms/ProfiBus
/ProfiBus
266 1 0 = Disable
1 = Enable