Datalogic Controller SC6000 Manual de usuario Pagina 49

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 80
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 48
PARAMETERS LIST
45
4
PARAMETER COMPLETE PATH SHC PT VALUE
MAIN SERIAL PORT
Data Tx /Comms/SerMain
/SerMain
510 1 0 = Disable
1 = Enable
Heartbeat /Comms/SerMain
/Heartbeat
- 1 0 = Disable
1 = Enable Unconditioned
2 = Enable Conditioned
Heartbeat Timeout /Comms/SerMain
/HeartbeatTimeOut
- 0 Range: 1 to 3600
Heartbeat Header
String
/Comms/SerMain
/heartbeatStart
- 3 Length: 0 to 32
Heartbeat Terminator
String
/Comms/SerMain
/HeartbeatStop
- 3 Length: 0 to 32
Send Diagnostic Info /Comms
/SerMain/SDSMAIN
- 1 0 = Disable
1 = Enable
MAIN SERIAL PORT PARAMETERS
Main Port
Communication
Mode
/Comms/SerMain
/Line/Mode
33 1 0 = Standard
2 = Siemens 3964
3 = Siemens RK512
Main Port Electrical
Interface
/Comms/SerMain
/Line/MainHW
10 1 0 = RS232
1 = RS485 Full Duplex
Handshake (RS232) /Comms/SerMain
/Line/FlowCtrl
57 1 0 = None
1 = Hardware (RTS/CTS)
2 = Software (Xon/Xoff)
Handshake (RS485) /Comms/SerMain
/Line/Flow485
60 1 0 = None
1 = Software (Xon/Xoff)
Baud Rate /Comms/SerMain
/Line/StdBaud
49 1 8 = 1200
1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 38400
6 = 57600
7 = 115200
Parity /Comms/SerMain
/Line/Parity
50 1 0 = None
1 = Odd
2 = Even
Data Bits /Comms/SerMain
/Line/Data
51 1 0 = 7
1 = 8
Stop Bits /Comms/SerMain
/Line/Stop
52 1 0 = 1
1 = 2
Checksum (Siemens) /Comms/SerMain
/Line/S3964Chk
- 1 0 = Disable
1 = Enable
Priority (Siemens) /Comms/SerMain
/Line/S3964Prio
- 1 0 = Low
1 = High
Header n. 5
(Siemens RK512)
/Comms/SerMain
/Line/SRKHead5
- 3 Length: 1
Header n. 6
(Siemens RK512)
/Comms/SerMain
/Line/SRKHead6
- 3 Length: 1
Header n. 9
(Siemens RK512)
/Comms/SerMain
/Line/SRKHead9
- 3 Length: 1
Vista de pagina 48