SC6000 HOST MODE PROGRAMMING
46
4
PARAMETER COMPLETE PATH SHC PT VALUE
Header n. 10
(Siemens RK512)
/Comms/SerMain
/Line/SRKHead10
- 3 Length: 1
Filler Character
(Siemens RK512)
/Comms/SerMain
/Line/SRKFillChar
- 3 Length: 1
Filler Position
(Siemens RK512)
/Comms/SerMain
/Line/SRKFillerPos
- 1 0 = Before Data
1 = After Data
AUXILIARY SERIAL PORT
Data Tx /Comms/SerAux
/SerAux
511 1 0 = Disable
1 = Enable
Heartbeat /Comms/SerAux
/Heartbeat
- 1 0 = Disable
1 = Enable Unconditioned
2 = Enable Conditioned
Heartbeat Timeout /Comms/SerAux
/HeartbeatTimeOut
- 0 Range: 1 to 3600
Heartbeat Header
String
/Comms/SerAux
/heartbeatStart
- 3 Length: 0 to 32
Heartbeat Terminator
String
/Comms/SerAux
/HeartbeatStop
- 3 Length: 0 to 32
Pass Through /Comms/SerAux
/PTSource
512 1 0 = Disable
1 = Enable
Send Diagnostic Info /Comms/SerAux
/SDSAUX
- 1 0 = Disable
1 = Enable
PASS THROUGH OPTIONS
String Max Length /Comms/SerAux
/PTOpt/PTMaxDim
513 0 Range: 0 to 32767
Termination String /Comms
/SerAux/PTOpt
/PTTerm
514 3 Length: 1 to 32
AUXILIARY SERIAL PORT PARAMETERS
Baud Rate /Comms/SerAux
/Line/StdBaud
53 1 8 = 1200
1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 38400
6 = 57600
7 = 115200
Parity /Comms/SerAux
/Line/Parity
54 1 0 = None
1 = Odd
2 = Even
Data Bits /Comms/SerAux
/Line/Data
55 1 0 = 7
1 = 8
Stop Bits /Comms/SerAux
/Line/Stop
56 1 0 = 1
1 = 2
BUILT-IN ETHERNET / LINE PARAMETERS
Status /Comms/Ethernet
/System/Status
90 1 0 = Disable
1 = Enable
Comentarios a estos manuales