SC6000 HOST MODE PROGRAMMING
28
4
PARAMETER COMPLETE PATH SHC PT VALUE
Max. Consecutive
Delayed Codes For
Node
/Operating
/ContEncMaxDelayOf
Code
- 0 Range: 0 to 255
Max. Safe Resync
For Node
/Operating
/ContEncMaxNode
Resync
- 0 Range: 0 to 255
Replicate same code
when symbologies
don't match
/Operating
/CodTypeFiltEn
- 1 0 = Disable
1 = Enable
Code Filter Depth /Operating
/CodeFilterDepth
502 0 Range: 0 to 127
Code Filter /Operating
/CodFiltToutEncEn
- 1 0 = Disable
1 = Timeout
2 = Encoder Steps
3 = Tx Line
Filter Timeout Value
(ms)
/Operating
/FilterTimeout
- 0 Range:40 to 15000
Filter Number of
Encoder Steps
/Operating
/FilterNumEncStep
- 0 Range:1 to 15000
Distance from (x,y,z)
origin to Tx Line
(mm)
/Operating
/ContTxLineDist
- 0 Range:100 to 20000
Replicate same code
when X positions
don't match
/Operating
/CodUseCoordinateX
- 1 0 = Disable
1 = Enable
Replicate same code
when Y positions
don't match
/Operating
/CodUseCoordinateY
- 1 0 = Disable
1 = Enable
Replicate same code
when Z positions
don't match
/Operating
/CodUseCoordinateZ
- 1 0 = Disable
1 = Enable
Encoder Divided by
2 (PackTrack only)
/Operating
/EncoderDividedBy2
- 1 0 = Disable
1 = Enable
Encoder Divided by
2 (Continuous only)
/Operating
/ContEncoderDividedBy2
- 1 0 = Disable
1 = Enable
Beam Shutter
Triggered
/Operating
/BeamShTriggered
- 1 0 = Disable
1 = Enable
Beam Shutter
Timeout
/Operating
/PktrBeamShutter
Timeout
- 1 0 = Disable
1 = 1 sec
2 = 10 sec
3 = 30 sec
4 = 1 min
5 = 5 min
6 = 10 min
7 = 15 min
Protocol Index /Operating
/ProtocolIndex
- 1 0 = Disable
1 = Enable
Hybrid System /Operating
/HybridSystem
- 1 0 = Disable
1 = Use SC6000 as Master
2 = Use SC6000 as Slave
PROTOCOL INDEX PARAMETERS / AUX